3. Press and hold the Mode button for 3 seconds, switch
to 12.8V Lithium mode.
Read the following information before
selecting a mode to avoid personal injury or
damage to the unit. The wrong selection of a
mode can lead to explosions.
6V NORM Charging voltage 7.4V | Charging current 0.8A |
Battery capacity 1.2-26Ah
Charging mode for 6V wet, gel, maintenance-free MF,
AGM, CA, VRLA and EFB batteries. After successful
completion of the charging process (battery full), an
automatic switch to trickle charge takes place.
12V NORM Charging voltage 14.7V | Charging current 0.8A |
Battery capacity 1.2-26Ah
Charging mode for 12V wet/wet, gel, maintenance-free
Deutsch . English . Français . Español
MF, AGM, CA, VRLA and EFB batteries. After successful
completion of the charging process (battery full), an
automatic switch to trickle charge takes place.
12.8V LITHIUM Charging voltage 14.5V | Charging current
0.8A | Battery capacity 2-15Ah
Charging mode for 12.8V lithium iron phosphate batteries
(4-cell LiFePO4). This mode is not available if the battery
voltage is outside 11.6-13.8V. This mode does not have a
trickle charge function.
Never use this mode for lead-acid batteries,
there is a risk of explosion and fire. Lithium
batteries do not necessarily have a battery
management system (BMS). Manufacturer's
specifications regarding voltage and charging
currents must be strictly adhered to.