Troubleshooting; Trouble Guide - Trane 4TYK8536B1000AA Technical & Service Manual

Dc-inverter air conditioners
Table of Contents

Advertisement

13. Troubleshooting

13.1 Trouble guide

Troubleshooting for normal malfunction
Troubleshooting
Air conditioner can not start up
The compressor starts or stops
frequently
Poor cooling
Sound from deforming parts
Water leakage
SS-SVM001A-EM
Possible Reasons of Abnormality
1. Power supply failure;
2. Trip of breaker or blow of fuse;
3. Power voltage is too low;
4. Improper setting of remote
controller;
5. Remote controller is short of
power.
The air inlet and outle t have been
blocked.
1. T he outdoor heat exchanger is
dirty, such as condenser;
2. There are heating devices indoors;
3. The air tightness is not enough,
and people come in and out too-
frequently;
4. Block of outdoor heat e xchanger;
5. Improper setting of temperature.
During system starting or stopping, a
sound might be heard.However, this
is due to the normal deformation of
plastic parts.
1. Drainage pipe is blocked or
broken;
2. Wrap of refrigerant pipe joint is
not closed completely.
How to Deal With
1. Check power supply circuit;
2. Measure insulation resistance to
ground to see if there is any
leakage;
3. Check if there is a defective con
tact or leak current in the power
supply circuit;
4. Check and set remote controller
again;
5. Change batteries.
Remove obstacles.
1. Clean the heat e xchanger of the
outdoor unit, such as condenser ;
2. Remove heating devices;
3. Keep certain air tightness indoors;
4. Remove block obstacles;
5. Check and try to set temperature
again.
It is not abnormal, and the sound will
disappear soon.
1. Change drainage pipe;
2. Re-wrap and make it tight.
49