8. Filed setting

8.1 Outdoor unit DIP switch

Capacity set
Dial it when the indoor units matched are in the following conditions.
Pump down mode
Actions:
The compressor runs with the target frequency, and without any protection when frequency
rises; The EEV runs with setting opening; Outdoor unit fan will run with the set fan speed.
Operation procedures:
Step 1:
Press the ON/OFF button to power off the appliance.
Step 2:
Disconnect the machine power.
Step 3:
Close the stop valve of the liquid piping with an Allen wrench in a clockwise direction.
32
DIP Switch Setting of Outdoor Unit (Optional setting)
1. Turn on all power sources before setting. Without turning on, the
switches settings are not refreshed and might be invalid. (36K)
2. Turn off all power sources before setting. Without turning off, the
switches settings are not refreshed and might be invalid.(48K/60K)
3. Mark of "
" indicates the position of DIP switches.
Outdoor unit model
36K
48K
60K
Indoor unit connect
30K
42K
48K
SS-SVM001A-EM