J. 50
MHz
TX
Mixer
(on 50 MHz
RF
Unit)
K. 50
MHz
TX
IF, Part
I (on 50 MHz
RF Unit)
1. Connect
the
test
equipment
as
shown
in the diagram above.
2. In
FM
mode,
tune
the
transceiver
to 52.00000 MHz, FM mode. Set the
MIC
Gain
fully
counterclockwise
and DRIVE
fully clockwise.
3. Press
the
MOX
button
and
adjust
VR2003
so that the spurii at
13.79
MHz
on
either
side
of the carrier
are at least 65dB down.
4. Press
the
MOX
button
again
to
return to receive.
Connect
the
test
equipment
as
shown
above,
with
the
AF
gener-
ator set for 3mV
@ 1 kHz.
Set the transceiver
to USB,
at the
center of the 144 MHz
band.
Set the DRIVE
control
fully clock-
wise,
press
the
MOX
button
to
transmit,
and
adjust
the
MIC
gain
for
5W
output.
Press
the
MOX
button again to return to receive.
Retune
the transceiver
to 52.00000
MHz.
Press
the
MOX
button
and
adjust
VR2002
for 5W output.
Press
the
MOX
button
to return
to receive,
and disconnect
the test
equipment.
V. FEX-736-220
A. 220 MHz
PLL Sub Loop (on 220 MHz
PLL
Unit
-
requires
oscilloscope
and
DC voltmeter)
1. Connect
the 'scope
to TP1001
and
the
DC
voltmeter
between
TP1002
and chassis ground.
2. Tune
the
transceiver
to
222.01999
MHz,
CW
mode,
and
adjust
T1002-
T1005
for
maximum
amplitude
on
the 'scope.
3. Adjust
L1016
for
4.2V
on
the
voltmeter.
4, Retune
the transceiver to 222.02000
MHz
and confirm
at least 0.6V
on
the voltmeter.
5. Disconnect
the
'scope
and
volt-
meter.
ie =
I,
4.
Connect
the voltmeter
between
the
exposed
lead
of R1055
and chassis
ground.
Tune
the
transceiver
to
222.01999
MHz,
CW
mode,
and
adjust
L1009
for 6.0V on the voltmeter.
Retune the transceiver to 222.02000
MHz
and confirm
at least
1.0V
on
the voltmeter.
Disconnect
the voltmeter.
1. Connect
the DC
voltmeter
between
the
exposed
lead
of
R1022
and
chassis
ground.
Connect
the
RF
voltmeter
to pin I of J1001.