Yaesu FT-736R Technical Supplement page 110

Hide thumbs Also See for FT-736R:
Table of Contents

Advertisement

F. 430
MHz
PLL
Sub
Loop
(on 430
MHz
ee
PLL Unit - requires DC voltmeter)
1. Connect
the
DC
voltmeter
between
3.
TP8001
and chassis ground.
2. Tune
the
transceiver
to 4xx.01999
MHz,
CW
mode,
and
adjust
L8004
4,
for 4.2V on the voltmeter.
3. Retune the transceiver to 4xx.02000
MHz
and
confirm
at least 0.6V
on
the voltmeter.
4. Disconnect
the voltmeter.
wo
G. 430 MHz
PLL
VCXO
(on 430 MHz
PLL
Unit
-
requires
RF
voltmeter
and
DC
i
voltmeter)
1. Connect
the
RF
voltmeter
to
the
exposed
lead of R8015,
and the DC
voltmeter
between
the exposed
lead
of R8017
and chassis ground.
RX UNIT ALIGNMENT
POINTS
58 —
Tune
the
transceiver
to 4xx.01999
MHz,
CW
mode.
Adjust
T8001
for maximum
RF
vol-
tage,
and
then
adjust
L8016
for
6.5V on the DC voltmeter.
Retune the transceiver to 4xx.02000
MHz
and confirm
at least
1.0V on
the DC voltmeter.
Retune
the
transceiver
to
the
center
of the
band,
FM
mode,
and
move
the RF voltmeter to J8001.
.
Adjust T8002
and CV8001
for maxi-
mum
on the RF voltmeter.
Disconnect
the voltmeters.

Advertisement