ASEM 6300P Panel PCs Catalog Numbers 6300P-121, 6300P-150, 6300P-156, 6300P-170, 6300P-185, 6300P-190, 6300P-215, 6300P-240 User Manual Original Instructions...
Page 2
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
EMI can Interference cause electronics to operate poorly, malfunction or stop performing Human Interface Device Hardware that enables a user to interact with a computer or mobile device Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
(2) A USB port located on the front panel is only available on 6300P panel PCs with standard profile aluminum bezels. (3) 6300P-….-…-Lxxx will feature 1 RVL port and 6300P-….-…-Mxxx will feature two RVL ports. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
(1) Catalog Number 6300P-…-…-Lxxx has one RVL port available; Catalog Number 6300P-…-…-Mxxx has two RVL ports available. (2) The USB port on the front bezel is only available on 6300P panel PCs with standard profile aluminum bezels. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
Cable kit: DVI and USB 2.0 (USB A type to USB B type) USB 2.0: 5 m (16.4 ft) Table 9 - RVL Components Cat. No. 6300V- Description RVLDV-RX ASEM RVL Receiver RVLDV-TX ASEM RVL Transmitter Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
EN 61000-3-2 Harmonic Emissions standard as specified by the EMC Directive of the European Union. Obtain permission from the local power authority before you connect any panel PC configuration that draws more than 75 W of AC power directly from the public mains. Rockwell Automation Publication 6300P-UMOO1D-EN-P - September 2023...
Vertical (Upright) Position (3.94) (3.94) 0° Preferred (2.76) (2.76) (2.76) 20° 20° Maximum Maximum (3.94) (3.94) (a) The Intel Core i7 processor throttles above 45 °C (113 °F) when the CPU is heavily loaded. Rockwell Automation Publication 6300P-UMOO1D-EN-P - September 2023...
(1) Power consumption value applies only when the port or slot is loaded. (2) 5 W is the maximum that the card can use. (3) 4 GB is included in the motherboard power estimate. Higher memory is in addition to the motherboard power estimates. Rockwell Automation Publication 6300P-UMOO1D-EN-P - September 2023...
6. Cut an opening for your panel PC model as specified in Figure 1 on page 7. Confirm that the cutout has been prepared according to the guidelines in Installation Requirements on page 8. Remove debris and metal fragments, then clean the cutout. Rockwell Automation Publication 6300P-UMOO1D-EN-P - September 2023...
ATTENTION: Risk of product damage. The mounting clips must be tightened to a torque of 0.2 N•m (1.8 lb•in). Rockwell Automation assumes no responsibility for water or chemical damage your panel PC or other equipment within the enclosure due to improper installation.
SHOCK HAZARD: All DC-powered models require a SELV (Safety Extra Low Voltage) power supply. The power supply is internally protected against reverse polarity. IMPORTANT To minimize ground loop currents and noise, Rockwell Automation recommends DC-powered models use only one grounded connection. Rockwell Automation Publication 6300P-UMOO1D-EN-P - September 2023...
Page 19
When installed correctly, both tabs of the clamp half-lock into place. 12. Reconnect the DC terminal block with the connector assembly to your panel PC chassis (G in Figure 13. Torque the DC terminal block flange screws to the values in Figure Rockwell Automation Publication 6300P-UMOO1D-EN-P - September 2023...
Do not disconnect power from the system until after the Windows Setup procedure is completed.If power is disconnected during this procedure your system image can become corrupt. Panel PC LEDs and Buttons on page 43 for LED status indicator definitions. Rockwell Automation Publication 6300P-UMOO1D-EN-P - September 2023...
- operator error in the control of the system. - proper use of E-stops and other safety practices. • You must provide means to achieve a safe state during anomalies and verify that the system has adequate redundancy for critical functions. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
Perform one of the following methods to properly shut down your panel PC. • Method 1: From the Start menu, click or select Shut Down. • Method 2: Press Ctrl+Alt+Delete, then click or select Shut Down. Use Start menu, click or select Shut Dow Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
Restart on page The POST initiates. 2. Press ‘F2’ to access the setup utility from the POST. To temporarily change the boot order, press the ‘F10’ key to directly access the Boot menu. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
Step 3: Create a Bootable USB drive Step 1: Download the Accessory Files You must be registered with the Rockwell Automation PCDC website and accept a User Agreement before you can download files. To download the accessory files, perform the following steps.
Page 25
13. Click the ‘SELECT’ button [B]. An Open window appears displaying downloaded files. 14. Select the ISO file that you downloaded from the Rockwell Automation PCDC site. The ‘Boot selection’ field updates to the selected ISO file [C] and the ‘Volume label’ field populates to the ISO file name [D].
‘D:’ drive, type ‘D:’, then press the Enter key. 6. Type ‘BackupImage.bat’, then press the Enter key. The following batch file script appears: IMPORTANT The wim file name cannot have any space characters. Use the underscore character instead. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
6. In the directory, type ‘RestoreImageUEFI.bat NameFile.wim’ where NameFile is the name of the file that you wish to restore. EXAMPLE Correct character structure example of a wim file: D:\RestoreImageUEFI.bat System_Image- PanelPC_6300_windows_10_2020_LTSC.wim Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
If the drive is not FAT32-formatted: proceed to step IMPORTANT If the USB drive must be FAT32-formatted, all files on the USB drive will be erased permanently. Before you proceed, transfer any required files to another location. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
9. Click the OK button. Download the Updated UEFI Files You must be registered with the Rockwell Automation PCDC website and accept a User Agreement before you can download the files. To download the updated UEFI, perform the following steps.
10. During POST, press F2 to enter the setup utility. 11. Use the right (6) arrow to toggle over to the ‘Save and Exit’ menu. 12. Use the down (2) arrow to toggle down to ‘Launch EFI Shell from the filesystem device’. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
Page 31
Restores the real-time default settings. 22. Select a preferred UEFI setting. 23. (Optional) Press the F9 key to select optimized defaults. 24. Press the F10 key to save and exit the set-up utility. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
The warning popup disappears after you press the Enter key, but the ‘Warning: SW4-3 = ON’ message remains until shut down your panel PC. 8. Manually shut down your panel PC. Shut Down on page Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
Page 33
14. Use the right (6) arrow to toggle over to the ‘Save & Exit’ menu. 15. Use the down (2) arrow to toggle down and select ‘Restore RealTime Defaults’. 16. (Optional) Press F9 to select optimized defaults. 17. Press F10 to save and exit the set-up utility. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
Page 34
Chapter 4 System Settings Notes: Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
Start menu, select ‘Restart’ or b. press Ctrl+Alt+Delete on an attached keyboard and select ‘Restart.’ 2. Press the ‘F2’ key. An initial setup screen appears. 3. Navigate over to the ‘Save and Exit’ menu. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
4. Select ‘ThinManager’ as ‘Boot Option #1’ for the boot option priority. 5. Navigate over to the ‘Advanced’ menu. 6. Navigate down to ‘Network Stack Configuration’. 7. Select ‘Network Stack’. 8. Navigate over to the ‘Save and Exit’ menu. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
Page 37
9. Navigate down to ‘Restore Legacy Support’. A ‘Restore Legacy Support’ popup menu appears. 10. Select ‘Next Boot’. A warning appears within the ‘Restore Legacy Support’ popup menu. 11. Select ‘OK’, then press the ‘F10’ key to save and exit the BIOS Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
Page 38
Chapter 5 Change Settings in BIOS Firmware Notes: Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
• Avoid contact with pins, leads, or circuitry. • Always hold components with a printed circuit board (PCB) by its edges and place it with the assembly side down. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
1. Use a #2 Phillips screwdriver to remove the three screws from the back cover of your panel PC. 2. Set the screws aside 3. Remove the cover from the chassis. 4. Set the cover aside. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
3. Locate the battery on the motherboard. 4. Remove the retired battery. 5. Install a new Lithium CR2032 3V battery with the positive polarity facing the locking tab. The UEFI resets to default values. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
6. Manually start your panel PC. See Manual Start on page 7. If necessary, reconfigure the UEFI settings if the default values are not suitable for your application. See Update the UEFI on page Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
No Color No Datalink is present. Datalink Green Datalink is established. Flashing Datalink is established and there is data Green transfer. No Color 10 Mbps Data Speed Green 100 Mbps Flashing 1000 Mbps (1 Gbps) Green Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
• IF the issue is with a specific software or driver THEN reinstall the software or driver. 5. If an issue cannot be identified by these steps or a fatal error occurs, see Rockwell Automation Support for technical support. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
Restart on page 2. During POST, press F2 to access the UEFI set-up utility. 3. Use the right (6) arrow on your numeric keypad to toggle over to the ‘Save and Exit’ tab. Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
PC until it is removed from the machine, panel, or rack. Rockwell Automation is not responsible for damage when it is shipped or transported while installed in a machine, panel, or rack and if it is not placed in its original packing material.
Page 47
6300P Panel PC User Manual Notes: Rockwell Automation Publication 6300P-UM001D-EN-P - September 2023...
Page 48
At the end of life, this equipment should be collected separately from any unsorted municipal waste. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Allen-Bradley, ASEM, expanding human possibility, FactoryTalk, Rockwell Automation, and ThinManager are trademarks of Rockwell Automation, Inc. Aptio is a trademark of AMI (American Megatrends Inc.).