Rockwell Automation Allen-Bradley 6300P User Manual
Hide thumbs Also See for Allen-Bradley 6300P:
Table of Contents

Advertisement

Quick Links

6300P Panel PC
Catalog Numbers 6300P-121, 6300P-150, 6300P-156, 6300P-
170, 6300P-185, 6300P-190, 6300P-215, 6300P-240
User Manual
Original Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Rockwell Automation Allen-Bradley 6300P

  • Page 1 6300P Panel PC Catalog Numbers 6300P-121, 6300P-150, 6300P-156, 6300P- 170, 6300P-185, 6300P-190, 6300P-215, 6300P-240 User Manual Original Instructions...
  • Page 2 If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
  • Page 3: Table Of Contents

    Shut Down ............. . . 21 Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 4 Disposal ..............46 Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 5: Preface

    Resistive ACPM Low Profile Aluminum glass, true flat PCAP ECPM JXPS Standard Stainless steel Resistive Acronyms Throughout this manual various acronyms are used. See Table 1 to identify the full term and definition. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 6: Additional Resources

    IC-TD003 Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines for installing a Rockwell Automation industrial system. Product Certifications website, https://rok.auto/certifications Provides declarations of conformity, certificates, and other certification details. Describes how to configure and use EtherNet/IP™ devices to communicate on the EtherNet/ EtherNet/IP™...
  • Page 7: Overview

    Long-distance support for up to two additional displays Additional Options TPM, PCI expansion slots, and additional communications (1) A USB port located on the front panel is only available on 6300P panel PCs with standard profile aluminum bezels. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 8: Panel Pc Options

    1920 x 1080, FHD (54.6) True Flat ECPM… AAPS… 24.0 Resistive 16:9: 1920 x 1080, FHD Standard aluminum (61.0) EAPS… ACPM… 24.0 Aluminum-glass PCAP 16:9: 1920 x 1080, FHD (61.0) True Flat ECPM… Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 9: Peripheral Connections

    2.5 in. SATA III HDD or SSD drive slot Front Bezel Note No. Description USB 2.0 port Side View Note No. Description CFast™ card slot (1) The USB port is only available on 6300P panel PCs with standard profile aluminum bezels. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 10: Approximate Dimensions

    (20.47) (12.28) ACPM 100 (3.94) 319.5 (20.79) (12.58) (0.24) (0.95) ECPM 70 (2.76) AAPS EAPS 24.0 (61.0) (23.00) (13.86) (0.24) (0.95) (3.94) (22.71) (13.54) ACPM ECPM (1) Dimensions are +0/-1 mm (0.04 in.). Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 11: Installation

    UL/cUL Mark Compliance Equipment with the UL/cUL mark complies with the requirements of UL 61010-1, UL 61010-2- 201, CSA C22.2 No. 61010-1, and CSA C22.2 No. 61010-2-201. Rockwell Automation Publication 6300P-UMOO1C-EN-P - December 2022...
  • Page 12: European Union Directive And Ukca Compliance

    - Do provide active cooling fan (required) when using expansion cards with total power consumption between 0…20 W. (a) The Intel Core i7 processor throttles above 45 °C (113 °F) when the CPU is heavily loaded. Rockwell Automation Publication 6300P-UMOO1C-EN-P - December 2022...
  • Page 13: Mounting Requirements

    • Adjustable torque screwdriver with M2 and M3 flat-blade bits • Cutting pliers • 1.5 mm torque-limiting screwdriver with hex key bit • Safety glasses • Multi-purpose electrician’s tool or wire stripper, cutter, and crimper tools • Rockwell Automation Publication 6300P-UMOO1C-EN-P - December 2022...
  • Page 14: Install The Panel Pc

    ATTENTION: To accomplish a proper seal and help prevent product damage: Tighten the mounting clips to a torque of 0.2 N•m (1.8 lb•in). Rockwell Automation assumes no responsibility for water or chemical damage to the panel PC or other equipment within the enclosure due to improper installation.
  • Page 15: Connect The Peripheral Cables

    Method 2: Use an Equipotential bonding cable (16mm ) to connect the grounds between the monitor and the 6300P panel PC. For further information, see Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Rockwell Automation Publication 6300P-UMOO1C-EN-P - December 2022...
  • Page 16: Connect The Dc Power

    1. Turn off the main power switch or breaker. 2. Remove the supplied nut, eyelet terminal, and washers from the ground screw. Table 4 on page 9 for the ground screw location. 3. Attach an external wire to the eyelet terminal. Rockwell Automation Publication 6300P-UMOO1C-EN-P - December 2022...
  • Page 17: Connect The Dc Power Connector Assembly

    SHOCK HAZARD: All DC-powered models require a SELV (Safety Extra Low Voltage) power supply. The power supply is internally protected against reverse polarity. IMPORTANT To minimize ground loop currents and noise, Rockwell Automation recommends DC-powered models use only one grounded connection. IMPORTANT The DC terminal block in...
  • Page 18 12. Reconnect the DC terminal block with the connector assembly to the panel PC chassis (G in Figure 13. Torque the DC terminal block flange screws to the values in Table 14. Turn on the main power switch or breaker. Rockwell Automation Publication 6300P-UMOO1C-EN-P - December 2022...
  • Page 19: Operation

    • operator error in the control of the system. • proper use of E-stops and other safety practices. You must provide means to achieve a safe state during anomalies and verify that the system has adequate redundancy for critical functions. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 20: Touch Screen Calibration

    No Datalink is present. Green Datalink is established. Datalink LED Datalink is established and there is Flashing Green data transfer. No Color 10 Mbps Data Speed LED Green 100 Mbps Flashing Green 1000 Mbps (1 Gbps) Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 21: Manual Start

    A keyboard and mouse must be connected to perform the following steps. • Method 1: From the Start menu, click or select Shut Down. • Method 2: Press Ctrl+Alt+Delete, then click or select Shut Down. Use Start menu, click or select Shut Down. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 22 Chapter 3 Operation Notes: Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 23: System Settings

    3. Use the numeric keypad on your connected keyboard to modify the setup utility. Table 13 to navigate to the applicable menu. Movement Numeric Keypad Key Function within Current Menu toggle between fields in current menu Down Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 24: Back Up/Restore Os Image

    Step 3: Create a Bootable USB drive Step 1: Download the Accessory Files You must be registered with the Rockwell Automation PCDC website and accept a User Agreement before you can download files. To download the accessory files, perform the following steps.
  • Page 25 13. Click the ‘SELECT’ button [B]. An Open window appears displaying downloaded files. 14. Select the ISO file that you downloaded from the Rockwell Automation PCDC site. The ‘Boot selection’ field updates to the selected ISO file [C] and the ‘Volume label’ field populates to the ISO file name [D].
  • Page 26: Back Up The Os Image

    ‘D:’ drive, type ‘D:’, then press the Enter key. 6. Type ‘BackupImage.bat’, then press the Enter key. The following batch file script appears: IMPORTANT The wim file name cannot have any space characters. Use the underscore character instead. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 27: Restore The Os Image

    EXAMPLE Correct character structure example of a wim file: D:\RestoreImageUEFI.bat System_Image- PanelPC_6300_windows_10_2020_LTSC.wim 7. Press the Enter key. A confirmation screen appears. The device name and capacity of your panel PC can differ from what is displayed in the conformation screen. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 28: Update The Uefi

    IMPORTANT If the USB drive must be FAT32-formatted, all files on the USB drive will be erased permanently. Before you proceed, transfer any required files to another location. 6. Right-click on the USB drive icon, then select Format. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 29: Download The Updated Uefi Files

    9. Click the OK button. Download the Updated UEFI Files You must be registered with the Rockwell Automation PCDC website and accept a User Agreement before you can download the files. To download the updated UEFI, perform the following steps.
  • Page 30: Update The Uefi

    11. Use the right (6) arrow to toggle over to the ‘Save and Exit’ menu. 12. Use the down (2) arrow to toggle down to ‘Launch EFI Shell from the filesystem device’. 13. Press the Enter key. The internal UEFI shell appears. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 31: Restore Factory Defaults

    When a password is forgotten or a critical setup item is erroneously changed, the UEFI setup utility cannot be entered. If the UEFI setup utility cannot be entered, the DIP switch must be accessed and changed to reset to the UEFI factory-default settings. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 32: Reset The Dip Switch

    11. Reinstall the cover. See Reinstall the Cover on page 12. Manually start your panel PC. See Manual Start on page 13. During POST, press the F2 key to enter the UEFI set-up utility. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 33 14. Use the right (6) arrow to toggle over to the ‘Save & Exit’ menu. 15. Use the down (2) arrow to toggle down and select ‘Restore RealTime Defaults’. 16. (Optional) Press F9 to select optimized defaults. 17. Press F10 to save and exit the set-up utility. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 34 Chapter 4 System Settings Notes: Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 35: Change Settings In Bios Firmware

    Start menu, select ‘Restart’ or b. press Ctrl+Alt+Delete on an attached keyboard and select ‘Restart.’ 2. Press the ‘F2’ key. An initial setup screen appears. 3. Navigate over to the ‘Save and Exit’ menu. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 36: Enable Thinmanager

    4. Select ‘ThinManager’ as ‘Boot Option #1’ for the boot option priority. 5. Navigate over to the ‘Advanced’ menu. 6. Navigate down to ‘Network Stack Configuration’. 7. Select ‘Network Stack’. 8. Navigate over to the ‘Save and Exit’ menu. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 37 9. Navigate down to ‘Restore Legacy Support’. A ‘Restore Legacy Support’ popup menu appears. 10. Select ‘Next Boot’. A warning appears within the ‘Restore Legacy Support’ popup menu. 11. Select ‘OK’, then press the ‘F10’ key to save and exit the BIOS Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 38 Chapter 5 Change Settings in BIOS Firmware Notes: Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 39: Maintenance And Service

    Transport your panel PC and replacement parts in static-safe containers, such as conductive tubes, bags, or boxes. • Keep electrostatic-sensitive parts in their containers until they arrive at the designated static-free work area. • Cover the designated work area with approved static-dissipating material: Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 40: Prepare For Maintenance And Service

    2. Use a clean sponge or a soft cloth dampened with water to wipe the surfaces of your panel PC. 3. Dry the display with a chamois or moist, cellulose sponge to avoid water spots. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 41: Remove/Reinstall The Cover

    UEFI must be reconfigured. 1. Perform all steps in Prepare for Maintenance and Service on page 2. Remove the cover from your panel PC. See Cover Screw Locations on page Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 42: Post-Configuration

    5. Manually start your panel PC. See Manual Start on page 6. If necessary, reconfigure the UEFI settings if the default values are not suitable for your application. See Update the UEFI on page Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 43: Troubleshooting

    If an issue cannot be identified by these steps or a fatal error occurs, see  Rockwell Automation Support on the back page for technical support. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 44: Integrated Display

    The video mode could be out of range. Change to the recommended resolution;  Picture is not clear symptom. Screen jitter or noisy video Check for proper video cable installation. Replace the suspected faulty cable. Reroute the cables or replace suspected faulty cables. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 45: System Default Options

    (4) place it in its original packing material.  Rockwell Automation is not responsible for damage when it is shipped or transported while installed in a machine, panel, or rack and if it is not placed in its original packing material.
  • Page 46: Disposal

    When a storage drive is part of your disposal, permanently erase any data on it or destroy the drive before disposing of it. Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 47 6300P Panel PC User Manual Notes: Rockwell Automation Publication 6300P-UM001C-EN-P - December 2022...
  • Page 48 At the end of life, this equipment should be collected separately from any unsorted municipal waste. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Allen-Bradley, expanding human possibility, FactoryTalk, Rockwell Automation, and ThinManager are trademarks of Rockwell Automation, Inc. Aptio is a trademark of AMI (American Megatrends Inc.).