Local Reset - AMC CT952GSM Use And Installation Manual

Telephone dialler
Table of Contents

Advertisement

Association of the SMS Transmission Event with SIM Card Programming
After a message has been saved on the SIM card, you need to set the event that causes its
immediate transmission. This parameter can be programmed in the SIM card and then transferred
with all the other parameters that have already been set for the vocal calls.
Procedure:
! Enter the phone book of the GSM mobile phone.
! Enter in the menu item "Find/Modify".
! Select the memory position (ranging from 1 to 8), corresponding to the message to be sent,
and confirm.
! Confirm in this position the telephone number that has already been stored for the vocal calls.
! In the NAME field, add the letter corresponding to the desired event.
Rif
Event
1
Input 1
2
Input 2
3
Input 3
4
Input 4
5
Input 5
6
Input 6
7
Input 7
8
Input 8
9
Input 3 RESET at +12V
0
Input 3 RESET to negative
a
Poor Voltage
b
Good Voltage
c
SIM due date
d
Life Test
! Confirm the name and once again the position.
! Perform a data transfer as shown under point 8 of the section SCHEDULING VOCAL CALLS
FROM THE GSM MOBILE PHONE.
Example:
field NUMBER
field NAME
position
It means the first SMS will be sent for the event POOR VOLTAGE to the telephone number stored in
the SIM card together with the text.
DIP-Switch Functions
1

LOCAL RESET

When on a state variation on the RESET terminal (from "open" to "close" or from "close" to "open")
results in the immediate block of all ongoing calls.
any (used for vocal calls only)
E
1
Rif
Message
A
SMS Message 1
B
SMS Message 2
C
SMS Message 3
D
SMS Message 4
E
SMS Message 5
F
SMS Message 6
G
SMS Message 7
H
SMS Message 8
I
SMS Message 9
J
SMS Message 10
K
SMS Message 11
L
SMS Message 12
M
SMS Message 13
N
SMS Message 14
19