Service Adjustments; Accessing Diagnostic Menu; Viewing The Service Mode Display; Control Keys Via Remote Commander - Sony KLV-22T550A Service Manual

Lcd color tv
Hide thumbs Also See for KLV-22T550A:
Table of Contents

Advertisement

KLV-22, 32 T550A
RM-GA016
Note
All data have been set for optical viewing for customers.
This section serves for informational purpose only.

6-1. Accessing Diagnostic Menu

1. While TV set on standby, press the following sequence on
the Remote commander (RMGA016).
On screen
display
The following menu will appear on the screen
MAIN_POWER_ERROR
5V_POWER_ERROR
AUDIO_ERROR
BALK_LIGHT_ERROR
TEMP_ERROR
2. To quit the diagnostic menu, turn off and on the set.

6-2. Viewing the Service Mode Display

1. While TV on standby mode, press the following sequence
on the Remote commander.
On screen
display
(if wrong key is pressed or passed 3 seconds during each
process, cancel entering the self-diagnosis display.)
Example on screen display:
CATEGORY
ITEM
[Category/Item name] Within 17 characters
T V
0 0 0
W B
0 0 0
W P R _ C
L O C T O P
P R O G R A M :
G T V :
N V M :
M O D E L
U S B
P R O G R A M :
2. To reset, press 8 – 0 –
3. To Exit, press the <I/1> key .

SERVICE ADJUSTMENTS

Channel 5
Volume (-)
0
0
0
0
0
Figure 1
Channel 5
Volume (+)
[Data] Within 7 characters
S E R V I C E
2 5 5
T M 0 . 0 7 0
M R 1 . 0 . 2
T D 0 . 1 0 0
I D :
7 0
S M 1 . 0 0 0
LOCTOP
PROGRAM: Show the Application version
GTV: Show the GTV Library version
NVM: Show the NVM version in the NVM data
(4bytes ASCII data)
MODEL ID: Show the MODEL ID in the NVM
data
USB
PROGRAM: Show the USB update micro
.
SECTION 6

6-3. Control keys via Remote Commander.

Buttons on the Remote Commander to access the service
menu items and adjust the data values.
Remote Button
POWER

6-4. Adjustment Method

6-4-1. Aging
1.
While TV on standby mode, press the following sequence
on the Remote commander.
On screen
Select AGING with 2 or 5 On the Remote Commander.
2.
3.
Select AGING MODE with 1 or 4 On the Remote
Commander.
4.
Select data value with 3 or 6 On the Remote
Commander to 1 to enable. Refer to Service Items
(Table 1) page 20.
5.
Press <I/1> to exit.
POWER
6.
When exit it will have the new data value and start aging.
7.
Aging condition:
Example on screen display:
T V
0 0 0
0 0 0
L O C T O P
U S B
– 18 –
Function
[1] / [4]
Item up / down
[2] / [5]
Category up / down
[3] / [6]
Data up / down
[3] /
[7]
Initialize data
[3] /
[8]
Test Reset
[3] /
[10] / [0]
Execute Data
<JUMP>
Change Mode
Channel 5
display
a) Supply voltage : Rating
b) Time: More than 20 minutes
c) Ambient Temp: 22-28 degrees
d) Input : Set no signal except digital and analog
RF(Video/Component/PC)
A G I N G
A G I N G
M O D E
P R O G R A M :
T M 0 . 0 7 0
G T V :
M R 1 . 0 . 2
N V M :
T D 0 . 1 0 0
M O D E L
I D :
P R O G R A M :
S M 1 . 0 0 0
LOCTOP
PROGRAM: Show the Application version
GTV: Show the GTV Library version
NVM: Show the NVM version in the NVM data
(4bytes ASCII data)
MODEL ID: Show the MODEL ID in the NVM
data
USB
PROGRAM: Show the USB update micro
Volume (+)
POWER
S E R V I C E
1
7 0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Klv-32t550a

Table of Contents