2-1. REMOTE ADJUSTMENT BUTTONS AND
INDICATORS
DISPLAY
MUTING
WEGA GATE
VOLUME (+)
RM-YA001
2-2. RESETTING THE USER MENU -
FACTORY RESET
The TEST RESET option resets all the customer adjustable data back to
the factory defaults.
NOTE: These sets have a sleep mode. To turn the sleep mode off, turn
the set on and access Service mode within 2 minutes.
POWER
1. To turn off sleep mode,
2. Press the following buttons on the Remote Commander within a
second of each other:
POWER
Off (Stand-by mode)
Volume +
POWER
3. Select SVC.
KLV-S26A10T/S32A10T
SECTION 2: SERVICE ADJUSTMENTS
POWER
TV/
VIDEO
ENTER
Onscreen cursor
and select button
On.
DISPLAY
Channel 5
On.
4. Select "TEST RESET".
5. Select "OK".
2-3. AGING MODE
Aging mode is designed to remove image retention from the screen.
NOTE: Once you enter into Aging Mode the Remote Commander no
longer functions with the set. To turn off the set, push the Power Button
on the set.
POWER
1. To turn off sleep mode,
2. Press the following buttons on the Remote Commander within a
second of each other:
POWER
Off (Stand-by mode)
Volume +
POWER
3. Select SVC.
4. Select "AGING MODE".
5. Select "OK".
2-4. WHITE BALANCE ADJUSTMENT
Equipment Needed
Video Generator (Leader LT 408 with NTSC Set-Up or equivalent)
to set the 60IRE and 20IRE NTSC signals)
Color Calibration (Minolta CA-210 or equivalent)
to read the White Balance Targets
POWER
1. To turn off sleep mode,
2. Press the following buttons on the Remote Commander within a
second of each other:
POWER
Off (Stand-by mode)
Volume +
POWER
3. Press "TV/VIDEO" to select Video 1.
4. Input 60IRE NTSC all Gray.
5. To display the User Menu, press
NOTE: Use the Onscreen cursors ( / / / ) and select button
navigate through the following screens:
KLV-S26A10T/S32A10T
On.
DISPLAY
Channel 5
On.
.
On.
DISPLAY
Channel 5
On.
WEGA GATE
.
to
16