4.2

Control cabinet installation

Extreme environmental conditions
Extreme environmental conditions can cause damage to the transmitter box.
• Avoid extreme environmental conditions.
• Protect the transmitter box from moisture and heat.
Incorrect installation
Mounting the device in a way that deviates from the documentation can impair its functionality.
• Mount the device only in the orientations shown in the documents.
The CU8803-000x transmitter box is designed for DIN rail mounting in control cabinets of machine and
system engineering. Please observe the environmental conditions prescribed for the operation (see Chapter
8 Technical data [} 21]).
The following dimensions of the device are given in mm.
71
Fig. 8: Dimensions
The transmitter box is mounted on a 35 mm DIN rail (according to EN 50022) via the back of the transmitter
box. Follow the steps below as shown in Figure 9 when mounting:
1. Hook the transmitter box into the DIN rail at an angle from above (section A).
2. Tilt the bottom of the transmitter box to the DIN rail and hook it in as well (section B).
ð You have mounted the transmitter box on the DIN rail.