Beckhoff CU8803-0000 Installation And Operating Instructions Manual
Beckhoff CU8803-0000 Installation And Operating Instructions Manual

Beckhoff CU8803-0000 Installation And Operating Instructions Manual

Cp-link 4 transmitter box - the one cable display link
Hide thumbs Also See for CU8803-0000:

Advertisement

Quick Links

Installation- and Operating instructions for
CU8803-0000
CP-Link 4 transmitter box – The One Cable Display Link
Version: 1.2
Date:
2018-11-13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CU8803-0000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Beckhoff CU8803-0000

  • Page 1 Installation- and Operating instructions for CU8803-0000 CP-Link 4 transmitter box – The One Cable Display Link Version: 1.2 Date: 2018-11-13...
  • Page 3: Table Of Contents

    Transport and Unpacking 3.1.1 Transport 3.1.2 Unpacking Mounting/ Demounting Connecting devices 3.3.1 Connecting cables 3.3.2 Connecting Power Supply 4 Operation CP-Link 4 Architecture Description Maintenance 4.2.1 Cleaning 4.2.2 Maintenance Shutting down 4.3.1 Disposal 5 Dimensions 6 Technical Data 7 Appendix CU8803-0000...
  • Page 4 Table of contents Beckhoff Support and Service 7.1.1 Beckhoff branches and partner companies 7.1.2 Beckhoff company headquarters Approvals for USA and Canada FCC Approval for USA FCC Approval for Canada CU8803-0000...
  • Page 5: Foreword

    Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co. KG. 1.1.6 Delivery conditions In addition, the general delivery conditions of the company Beckhoff Automation GmbH & Co. KG apply. CU8803-0000...
  • Page 6: Description Of Safety Symbols

    • the operation manual is in good condition and complete, and always available for reference at the location of the product • none of the safety and warning notes attached to product are removed, and that all notes remain legible. CU8803-0000...
  • Page 7: Product Description

    • Metal housing for DIN rail installation • CP-Link 4 transfers USB 2.0 with 100 Mbit/s and DVI • 24 V input for power supply of the CU8803 transmitter box and the Control Panel • Protection class IP 20. CU8803-0000...
  • Page 8: Connections

    Note function of the touchscreen. 2.2.2 USB Input (X10) Connector USB TYP-B LP-mount. WS The CP-Link 4 transmitter box CU8803-0000 is connected with the Industrial PC via the USB input (X10). The maximum cable length is 1 m. Signal Signal...
  • Page 9: Dvi Input (X20)

    Product Description 2.2.3 DVI Input (X20) Connector DVI-D 3x8pole Digital LP-mount. The CP-Link 4 transmitter box CU8803-0000 is connected with the Industrial PC via the DVI input (X20). The maximum cable length is 1 m. Signal Signal TMDS Data 2- n.c.
  • Page 10: Led-Diagnostics

    2.3 LED-Diagnostics Allocation State Meaning Power supply no power supply lights green 24 V connected no connection to the Control Panel Connection lights green connection to the Control Panel established Activity no image data transmission flashes yellow DVI data transmission CU8803-0000...
  • Page 11: Installation

    4. Please keep the associated paperwork. It contains important information for handling the unit 5. Check the contents for visible shipping damage. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service. CU8803-0000...
  • Page 12: Mounting/ Demounting

    Installation 3.2 Mounting/ Demounting The CP-Link 4 transmitter box CU8803-0000 can be snapped onto a 35 mm mounting rail conforms to EN 50022: To release the CP-Link 4 transmitter box CU8803-0000 from the mounting rail, press the device downwards till you can remove it from the rail.
  • Page 13: Connecting Devices

    • Switch off all the devices that are to be connected • Disconnect all the devices that are to be connected from the power supply • Connect all the cables between the CU8803-0000 and the devices that are to be connected • Reconnect all devices to the power supply.
  • Page 14: Operation

    Don’t connect power supply socket if using One Cable technology If using the CP-Link 4 - One Cable Display Link technology, do not connect anything to Attention the power supply socket of the Panel. The maximum cable lengths for DVI- and USB connection are 1 m. CU8803-0000...
  • Page 15: Maintenance

    The device can be cleaned with a soft, damp cloth. Do not use any aggressive cleaning materials, thinners, scouring material or hard objects that could cause scratches. 4.2.2 Maintenance The CU8803-0000 CP-Link 4 transmitter box is maintenance-free. 4.3 Shutting down 4.3.1 Disposal Observe national electronics scrap regulations Observe the national electronics scrap regulations when disposing of the device.
  • Page 16: Dimensions

    The product is characterized by small overall installed size. With a height of 100 mm, the module dimensions exactly match those of the Beckhoff Bus Terminals. Together with the lowered connector surfaces, this means that it can be used in a standard terminal box with a height of 120 mm...
  • Page 17: Technical Data

    Technical Data 6 Technical Data Product name CU8803-0000 Inputs 1 USB input with USB B socket to be connected to the PC 1 DVI input with DVI-D socket to be connected to the PC Output 1 CP-Link 4 output with RJ45 socket for Cat.6...
  • Page 18: Appendix

    Please contact your Beckhoff branch office or partner company for local support and service on Beckhoff products! The contact addresses for your country can be found in the list of Beckhoff branches and partner companies: www.beckhoff.com. You will also find further documentation for Beckhoff components there.
  • Page 19 Technical modifications to the device may cause the loss of the FCC approval. Note 7.4 FCC Approval for Canada FCC: Canadian Notice This equipment does not exceed the Class A limits for radiated emissions as described in the Radio Interference Regulations of the Canadian Department of Communications. CU8803-0000...