Battery Type Selection
1.
Press and hold the only Select Button for about 5 seconds until the LED flashes.
2.
Light quick presses will move the LED from Lead--> AGM--> Lithium--> Type 2+Lead-->
Type 2+AGM--> Type 2+Lithium--> Lead.
3.
Stop at the chosen battery type and wait till LED stops flashing to confirm your selection.
Connections
After both input and output are connected, the charger will have output after 10 Sec.
SBC-6111
Fig 3.: Terminals
Vin:
Vout:
GND:
Temp sensor:
12V:
Ignition:
Alarm:
Ground:
Vibration sensor:
Charger Control Modes
There are 3 automatic charge modes plus one manual ON-OFF to switch on and off the charger to give the
optimal charging current to the auxiliary battery.
Automatic Ignition Control Mode
It synchronizes ON/OFF of the DC-DC charger with the car's ignition.
This mode requires connection to the car's Ignition Signal Terminal 15 electrical circuit which gives out a
positive DC Voltage from the car's electrical wiring when the ignition is turned on. The ignition control will set
to ON once the Ignition Pin is applied with 9-16V voltage. The charging operation stops when Ignition is off
& engine stops running.
This mode is recommended for all alternator types including Europe 6, 6+plus with start/ stop energy saving.
Manual Control
You can wire a contact switch with one end to the Ignition Pin and the other to 12V Pin. Shorting both pins
will turn on the charger, disconnect will turn off the charger.
Vibration Sensor Control Mode
Switch ON the vibration sensor to enable build-in vibration sensor
The built in vibration sensor with special software control turns on the charging when trains of vibrations are
detected. Installation is simple and quick and without touching the car's electrical system for the sensor to
work.
Input positive (Ve+) terminal.
Output positive (Ve+) terminal.
Ground (Ve-) terminal for input and output. It is common ground for input and output.
Temperature sensor connection port.
Positive 12V 50mA for ignition control use.
Ignition control pin, for connecting to terminal 15 of car.
Alarm output pin. 12V 100mA for external alarm.
Ground pin for alarm.
Switch on/off of vibration sensor.