Download Print this page

Operation Description; Power Supply Operation Description; Adjustment; Output Voltage Adjustment - Sony CMA-D2 Service Manual

Camera adaptor
Hide thumbs Also See for CMA-D2:

Advertisement

Operation
POWER switch
Set the POWER switch to ON.
The unit supplies DC power to the connected camera via
the CAMERA connector.
The unit outputs video camera signals and inputs sync
signal depending on the camera and the camera cable being
used.
For details, see "Connections" on pages 5 to 8.
Specifications
anne AR rN Sines
Calas
oc
General :
Output connectors
VIDEO OUT (BNC type) (1)
S VIDEO (4-pin mini DIN) (1)
CAMERA (4-pin) (1)
ane
Wong
Power requirements:
CMA-D2: 120 V AC, 50/60 Hz
CMA-D2CE: 100 to 240 V AC,
50/60 Hz
DC output
I3VDC,1.3A
Operating temperature
O°C to +40°C (32°F to 104°F)
Input/output connector
CAMERA (12-pin) (1)
Storage temperature
—20°C to +60°C (—4°F to 140°F)
Dimensions
210 x 44 x 200 mm (w/h/d)
(8 3/3 X 1 3/4 x 7 7/8 inches)
excluding projecting parts
Mass
1.1 kg (2 lb 7 02)
AC power cord (1)
Operating instructions (1)
Design and specifications are subject to change without
Input/Output Connectors
_
input connector
GENLOCK IN (BNC
type)
CMA-D2/D2CE
cok
re
SECTION
2
OPERATION
DESCRIPTION
2-1.
POWER SUPPLY OPERATION DESCRIPTION
120 V AC (CMA-D2) or 100 to 240 V AC (CMA-D2CE)
is
rectified
by the bridge diode
(BRI)
and
smoothed
by the
electrolytic capacitor (C6).
|
And it 1s switched by the transistor (Ql), transformed by the
transformer (T1), rectified by the diode (D51) and smoothed by
the electrolytic capacitors (C51, C52), and it goes cut.
The shunt regulator (IC51) detects its output and it is fed back by
the photocoupler (PC1).
So the output voltage is regulated.
This
power
supply
has
the
overcurrent
protector
and
the
overvoltage protector for output.
The overcurrent protector controls the output current by detecting
the primary current when the output is in the overcurrent state.
The overvoltage protector is using the zener diode (ZD51) at the
output.
SECTION
3
ADJUSTMENT
EQUIPMENT
REQUIRED
@ DC Voltmeter
3-1.
OUTPUT
VOLTAGE
ADJUSTMENT
Measurement point : CAMERA (4-pin) pin | (+) pin 3 (—)
Adjustment point
:@VRI1
Specification
-13 40.2 Vde
Adjustment method : Feed the rated power supply to AC IN
and be sure to don't be connected to the
load.
VR1
@
Main board (Component
side)
= ing
ib RSE
ERIS
SR
EP
TB NR
EI
DSO
DEE
ELE
RAISE
AES ET
EES

Advertisement

loading

This manual is also suitable for:

Cma-d2ce