Standards and Certifications

The Honeywell BW™ Ultra gas detector is in conformity with
the following standards and certifications:
Approvals:
Approved by UL to both U.S. and Canadian Standards
UL 913, 8th Edition
UL 60079-0, 7th Edition
UL 60079-1, 7th Edition.
UL 60079-11, 6th Edition
ANSI/ISA 60079-29-1 (12.13.01) - 2013
CSA C22.2 No.152-M1984 (R2016)
CSA C22.2 No. 60079-0:19
CSA C22.2 No. 60079-11:14
CSA C22.2 No. 60079-1:16
UL: E480011
Class I, Division I, Group A, B, C and D, Temperature code
T4, -40 ≤ Tamb ≤ +50°C
Class I, Zone 0, AEx ia IIC T4 Ga, -40 ≤ Tamb ≤ +50°C
(without LEL and IR sensor installed)
Class I, Zone 0, AEx da ia IIC T4 Ga, -40 ≤ Tamb ≤ +50°C
(with LEL sensor installed and without IR sensor installed)
Class I, Zone 0, AEx ia IIC T4 Ga, -20°C ≤ Tamb ≤ +50°C
(with IR sensor installed and without LEL sensor installed)
Class I, Zone 0, AEx da ia IIC T4 Ga, -20°C ≤ Tamb ≤ +50°C
(with LEL and IR sensor installed)
CSA: E480011
Class I, Division I, Group A, B, C and D, Temperature code
T4, -40 ≤ Tamb ≤ +50°C
Ex ia IIC T4 Ga, -40 ≤ Tamb ≤ +50°C
(without LEL and IR sensor installed)
Ex da ia IIC T4 Ga, -40 ≤ Tamb ≤ +50°C
(with LEL sensor installed and without IR sensor installed)
Ex ia IIC T4 Ga, -20°C ≤ Tamb ≤ +50°C (with IR sensor
installed and without LEL sensor installed)
Ex da ia IIC T4 Ga, -20°C ≤ Tamb ≤ +50°C (with LEL and IR
sensor installed)
ATEX: DEMKO 18 ATEX 1833X
UKCA: UL21UKEX2006X
EN IEC 60079-0:2018
EN 60079-11:2012
EN 60079-1:2014
EN 60079-26:2015
I M1 Ex ia I Ma, -20°C ≤ Tamb ≤ +50°C
II 1 G Ex ia IIC T4 Ga, -40°C ≤ Tamb ≤ +50°C
(without LEL and IR sensor installed)
I M1 Ex da ia I Ma, -20°C ≤ Tamb ≤ +50°C
BW Ultra User Manual
II 1 G Ex da ia IIC T4 Ga, -40°C ≤ Tamb ≤ +50°C
(with LEL sensor installed and without IR sensor installed)
I M1 Ex db ia I Ma, -20°C ≤ Tamb ≤ +50°C
II 2 G Ex db ia IIC T4 Gb, -20°C ≤ Tamb ≤ +50°C
(with IR sensor installed)
IECEx: UL 18.0061X
IEC 60079-0:2017
IEC 60079-11:2011
IEC 60079-1:2014
IEC 60079-26:2014
Ex ia I Ma, -20°C ≤ Tamb ≤ +50°C
Ex ia IIC T4 Ga, -40°C ≤ Tamb ≤ +50°C
(without LEL and IR sensor installed)
Ex da ia I Ma, -20°C ≤ Tamb ≤ +50°C
Ex da ia IIC T4 Ga, -40°C ≤ Tamb ≤ +50°C
(with LEL sensor installed and without IR sensor installed)
Ex db ia I Ma, -20°C ≤ Tamb ≤ +50°C
Ex db ia IIC T4 Gb, -20°C ≤ Tamb ≤ +50°C
(with IR sensor installed)
The following additional previous editions of Standards
noted under the "Standards" section of this Certificate were
applied to integral Components as itemized below. There are
no significant safety related changes between these previous
editions and the editions noted under the "Standards" section.
Product
Certificate Num
Dynament Ltd.
IECEx FTZU
Gas Sensors Type
15.0002U
MSH2ia***
City Technology
Limited, Miniature
IECEx ULD
Combustible Gas
16.0016U
Sensor - 1 LEL 75
JPEx
DEK21.0013X
JNIOSH-TR-46-1: 2015
JNIOSH-TR-46-6: 2015
Ex ia IIC T4 Ga, -40°C ≤ Tamb ≤ +50°C
(without LEL and IR sensor installed)
DEK21.0014X
JNIOSH-TR-46-1: 2015
JNIOSH-TR-46-2: 2018
JNIOSH-TR-46-6: 2015
Standards
IEC 60079-0
Edition 2011
IEC 60079-0
Edition 2011