Configure the Detector

You can configure the Honeywell BW™ Ultra detector's
device and sensor using Safety Suite Device Configurator.
Necessary to configure detector settings:
• Honeywell BW™ Ultra detector
• IR Link adapter or IntelliDoX docking station
• Computer with Safety Suite Device Configurator software installed.
For device settings, a startup message can be added;
Confidence Compliance Beep can be activated, bump tests
can be forced, stealth mode can be enabled, etc.
For sensor settings, the calibration gas type and frequency
can be changed, the bump test interval and alarm setpoints
can be set, STEL and TWA can be selected, etc.
You can perform some other calibrations with Safety Suite
Device Configurator.
• Latching Alarms
• IntelliFlash Mode
• IntelliFlash Interval (seconds)
• Confidence/Compliance Beep
• Confidence/Compliance Beep Interval (seconds)
• Datalog Interval (seconds)
• Language
• Hole Watch Mode
• Disable Button Power Off
• Time Zone/Time Settings. (Time Zone and UTC offset in
minutes)
• LEL over span ( as it is used by both whittle LEL & IR LEL)
• STEL / TWA back up
• Clear Peaks Type
• BLE enable
• Normal display
• Pairing Code
General Sensor Settings (for all sensors)
• Sensor Enable/Disable
• Calibration Gas Concentration
: When the operator configures the Honeywell BW™ Ultra using
Note
Safety Suite Device Configurator, Honeywell strongly recommends
reviewing the detector's settings before the operation to ensure that
settings were applied successfully and comply with performance
requirements.
Custom configuration created in Safety Suite Device
Configurator can be used to configure detector settings.
Example: Five detectors must have the same bump test
reminders and alarm setpoints. Each detector could be
configured separately or Safety Suite Device Configurator
can be utilized to create a custom settings configuration.
This configuration can then be loaded on each detector.
This saves time and allows settings to be managed from
BW Ultra User Manual
one location.

Connect With IntelliDoX

If a detector's calibration is overdue and the forced
calibration feature is enabled, the calibration can be
performed with an IntelliDoX docking station or through
the calibration option from the detector's main menu.

Connect With an IR Link

The detector can be paired with an IR link, aka dongle.
There is an IR connection at the bottom of the detector that
allows Safety Suite Device Configurator configurations to
be efficiently transferred to multiple detectors. The IR link
will also allownew firmware to be transferred to detectors
or data/event logs to be transferred to Safety Suite Device
Configurator.
Note: You should have the IR Connectivity Kit (sold separately) to
transfer the data from a computer to the detector.