BEFORE INSTALLING THE WIRED CONTROLLER
•
This manual provides instructions for installing the wired
CAUTION
controller. Please refer to the wiring diagram of this installation
manual for connecting the wired controller with indoor unit.
•
The wired controller operates in a low voltage loop circuit.
Strictly DO NOT directly contact the high voltage cable
above, such as 115V,220V,380V. DO NOT wire this type of
cabling in the said loop; wiring clearance between configured
tubes should range between 300~500mm or above.
•
The shielded wire of the wired controller must be grounded
firmly.
•
After completing the wire controller connection, DO NOT use
Megger tester to check the insulation. That may damage the
product.
A maximum of two controllers may be installed on a system and
the mix may contain any of the following three controllers:
NOTE
CNTRLDRCINW / CNTRLDRCIPW / CNTRLDRCIPB
Rinnai
8
DRCi R32 Wired Controller OIM