Zf180-300 Unit Accessory Weights; Utilities Entry; Supply Fan Vfd Weights, In Lbs; Zf180-300 Unit Dimensions Front View - York ZF210 Instruction Manual

Hide thumbs Also See for ZF210:
Table of Contents

Advertisement

Table 3: ZF180-300 Unit Accessory Weights
Unit Accessory
Economizer
Power Exhaust
1
Electric Heat
2
Gas Heat
Double Wall
Motorized Damper
Barometric Damper
Econ./Motorized Damper Rain Hood
Econ./Power Exhaust Rain Hood
Wood Skid
Roof Curb
Hot Gas Bypass
Supply Fan VFD
1. Weight given is for the maximum heater size available (54KW).
2. Weight given is for the maximum number of tube heat exchangers available (8 tube).
Figure 5: ZF180-300 Unit Dimensions Front View
Table 4: Utilities Entry
Opening Size
Hole
Diameter
1-1/8" KO
A
3/4" NPS (Fem.)
3-5/8" KO
B
3" NPS (Fem.)
C
2-3/8" KO
D
1-11/16" Hole
1. One-inch Gas Piping NPT Required.
2. Opening in the bottom to the unit can be located by the slice in the
insulation.
Note: All entry holes should be sealed to prevent rain water entry
into building.
Johnson Controls Unitary Products
Weight (lbs.)
Shipping
165
90
40
240
260
150
50
60
95
220
190
10
BLOWER ACCESS
(Location Of
FIELD-SUPPLIED
BLOWER MOTOR ACCESS
Optional VFD)
DISCONNECT SWITCH
(Location Of Optional
LOCATION
VFD Bypass)
BLOWER
COMPARTMENT
ACCESS
(Auxiliary)
D O T P L U G
( F o r p r e s s u r e
D r o p R e a d i n g )
ELECTRIC
G A S H E A T
A C C E S S
V E N T A IR
O U T L E T
H O O D S
C O M B U S T IO N
A IR IN L E T
H O O D
6 - 3 /8 "
( C )
G A S S U P P L Y
E N T R Y
C O N T R O L B O X
3 5 "
A C C E S S
F R ON T
V I E W
1 1 - 1 /8 "
U N IT B A S E W IT H R A IL S
S h o w n s e p a r a te l y to i l l u s tr a te
( D )
G A S S U P P L Y
B o tto m D u c t o p e n i n g s , P o w e r
E N T R Y
a n d G a s P i p i n g C o n n e c ti o n
l o c a ti o n s
N O T E :
F o r c u r b m o u n te d u n i ts , r e fe r to th e c u r b h a n g e r
d i m e n s i o n s o f th e c u r b fo r th e p r o p e r s i z e o f th e
s u p p l y a n d r e tu r n a i r d u c t c o n n e c ti o n s .
Used For
Front
Control Wiring
Bottom
Front
Power Wiring
Bottom
1
Gas Piping (Front)
1,2
Gas Piping (Bottom)
Operating
160
85
40
240
260
150
45
55
90
220
185
10
See Table 5
E C O N O M IZ E R / M O T O R IZ E D D A M P E R ,
F IX E D O U T D O O R IN T A K E A IR A N D
P O W E R E X H A U S T R A IN H O O D S
( S e e d e ta i l " Y " )
48-5/8" (15 Ton)
52-5/8" (17.5 & 20 Ton)
2 1 "
5 "
7 - 1 /8 "
9 - 3 /4 "
9 2 "
5 - 7 /8 "
4 6 - 5 /8 "
1 1 - 1 /2 "
B O T T O M S U P P L Y
A N D R E T U R N
A IR O P E N IN G S
( S e e N o te )
R E T U R N
A IR
3 3 "
S U P P L Y
A IR
2 - 3 /4 "
2 1 - 1 /2 "
( B )
P O W E R W IR IN G
E N T R Y
( A )
C O N T R O L W IR IN G
8 - 1 /8 "
E N T R Y
4 6 - 5 /8 "
9 - 1 /4 "
1 2 - 1 /2 "
9 - 3 /4 "
Table 5: Supply Fan VFD Weights, In Lbs.
Supply Fan Motor
W/O Manual Bypass
10.0 hp
15.0 hp
W/Manual Bypass
10.0 hp
15.0 hp
C O M P R E S S O R
A C C E S S
( S e e d e ta i l " X " )
O P T IO N A L C O IL
G U A R D K IT
C O N D E N S E R
C O IL S
( A )
C O N T R O L W IR IN G
E N T R Y
( B )
P O W E R W IR IN G
E N T R Y
R E T U R N A I R
3 - 3 /4 "
S U P P L Y A I R
OU T D OOR A I R
OU T D OOR A I R
( E c o n o m i z e r )
230V
5.0 hp
25
7.5 hp
30
30
30
5.0 hp
30
7.5 hp
35
35
40
1088917-YIM-B-1014
460V
575V
25
30
30
30
30
35
30
40
30
35
35
35
35
40
35
45
9