1088917-YIM-B-1014
Nomenclature
15-25 Ton Sunline Magnum™ Model Number Nomenclature
Z F 180 N24 A 2 A AA 3 0 1 2 4 A
Product Category
Z = A/C, Single Pkg., R-410A
Product Identifier
F = 10 thru 11 EER A/C
Nominal Cooling Capacity
180 = 15 Ton
210 = 17.5 Ton
240 = 20 Ton
300 = 25 Ton
Heat Type and Nominal Heat Capacity
C00 = Cooling Only. No field installed
electric heat
Gas Heat Options
N24 = 240 MBH Output Aluminized Steel
N32 = 300 MBH Output Aluminized Steel
N32 = 320 MBH Output Aluminized Steel
S24 = 240 MBH Output Stainless Steel
S32 = 300 MBH Output Stainless Steel
S32 = 320 MBH Output Stainless Steel
Electric Heat Options
E18 = 18 KW
E36 = 36 KW
E54 = 54 KW
E72 = 72 KW
Note:
1. ZF180 Only
Airflow
A = Std. Motor
D = Std. Motor/Motorized Damper
E = Std. Motor/Motorized Damper/Barometric Relief
F = Std. Motor/Low Leak Econ
G = Std. Motor/Low Leak Econ/Power Exhaust
H = Std. Motor/Low Leak Econ/Barometric Relief
N = Hi Static
R = Hi Static/Motorized Damper
K = Hi Static/Motorized Damper/Barometric Relief
L = Hi Static/Low Leak Econ
M = Hi Static/Low Leak Econ/Power Exhaust
T = Hi Static/Low Leak Econ/Barometric Relief
2 = Low Static
2
5 = Low Static/Motorized Damper
2
6 = Low Static/Motorized Damper/Barometric Relief
U = Low Static/Low Leak Econ
2
V = Low Static/Low Leak Econ/Power Exhaust
W = Low Static/Low Leak Econ/Barometric Relief
Notes:
1. Downflow Only
2. Available only in the ZF300.
4
1
1
Product Generation
3 = Third Generation
1
AA = None
AB = Phase Monitor
1
AC = Coil Guard
AD = Dirty Filter Switch
AE = Phase Monitor & Coil Guard
AF = Phase Monitor & Dirty Filter Switch
2
AG = Coil Guard & Dirty Filter Switch
AH = Phase Monitor, Coil Guard & Dirty Filter Switch
1,2
RC = Coil Guard & American Flag
2
TA = Technicoat Condenser Coil
TJ = Technicoat Evaporator Coil
TS = Technicoat Evaporator & Condenser Coils
Voltage
EA = ElectroFin Condenser Coil
EJ = ElectroFin Evaporator Coil
2 = 208/230-3-60
ES = ElectroFin Cond & Evap Coils
4 = 460-3-60
5 = 575-3-60
ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be
located in digits 15-18.
Installation Options
A = No Options Installed
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
Product Style
A = Style A
Configuration Options (not required for all units)
These four digits will not be assigned until a quote is requested, or an order placed.
SS Drain Pan
CPC Controller, DFS, APS
Johnson Controller UNT 1126 (N2 protocol), DFS, APS
Honeywell Controller, DFS, APS
Novar Controller, DFS, APS
Simplicity®Smart Equipment w/ BAS Option (BACnet, MS/TP)
FDD (Fault Detecter Diagnostics)
York Commercial Comfort System (YCCS) Rtu Controller
Hot Gas Bypass (Standard on VAV, Optional on CV)
IntelliSpeed with VFD
IntelliSpeed, VFD and Manual Bypass
IntelliSpeed, VFD Ready (for customer-provided, field-installed drive)
Variable Air Volume, VFD (not available with factory installed BAS options)
Variable Air Volume, VFD with BAS Option (BACnet, MS/TP) (not available with factory installed BAS options)
Variable Air Volume, VFD and Manual Bypass (not available with factory installed BAS options)
Variable Air Volume, VFD and Manual Bypass with BAS Option (BACnet, MS/TP) (not available with factory installed BAS options)
Variable Air Volume, VFD (BAS ready)
Variable Air Volume, VFD and Manual Bypass (BAS ready)
Variable Air Volume, VFD Ready (for customer provided, field installed drive)
Variable Air Volume, VFD Ready with BAS Option (BACnet, MS/TP) (for customer-provided, field-installed drive)
2" Pleated Filters, MERV 7
4" Pleated Filters, MERV 13
BAS Ready Economizer w/Belimo
1
Double Wall Construction
2
Any Combination of Additional Options that Don't Have an Option Code Pre-assigned
Notes:
1. BAS Ready econ requires input from a field installed BAS control. Not available with
factory installed BAS controls.
Additional Options
Standard Cabinet
Hinged Filter Door & Tool Free Access Cabinet
BA = Hinged Filter Door & Tool Free Access Panels
BB = Phase Monitor, Hinged Filter Door & Tool Free
Access Panels
BC = Coil Guard, Hinged Filter Door & Tool Free
Access Panels
BD = Dirty Filter Switch, Hinged Filter Door &
Tool Free Access Panels
BE = Phase Monitor & Coil Guard, Hinged Filter
Door & Tool Free Access Panels
BF = Phase Monitor & Dirty Filter Switch, Hinged
Filter Door & Tool Free Access Panels
BG = Coil Guard & Dirty Filter Switch, Hinged Filter
Door & Tool Free Access Panels
BH = Phase Monitor, Coil Guard & Dirty Filter Switch,
Hinged Filter Door & Tool Free Access Panels
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Options 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5
Options
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Johnson Controls Unitary Products