Internal Controls; Spring Tension Arm - Lincoln Electric 11033 Operator's Manual

Wire feeder
Table of Contents

Advertisement

B-5
Rotate the WFS knob until the desired parameter is
displayed.
CV/CC Mode:
WFS Units:
2. Activate and release the GAS PURGE switch to
select the parameter. The present value will then
display in the right hand side of the display.
Example:
3. Rotate the WFS knob to change the parameter set-
ting.
CV/CC MODE:
• "CU" for Constant Voltage power sources
• "CC" for Constant Current power sources
WFS UNITS:
• "US" for in/min
• "Eur" for m/min
4. Press the GAS PURGE switch to save the setting.
The LN™-15 will then return to the original "Press
Spin" mode in step 1.
5. To exit the "Press Spin" set-up mode, turn off power
to the LN™-15, or simply wait 15 seconds and the
LN™-15 will enter normal operation.
OPERATION
WFS
LN™-15 ACROSS THE ARC MODEL & (CE)

INTERNAL CONTROLS

COLD FEED/
GAS PURGE
SWITCH
SPRING
TENSION
ARM
FLOWMETER

SPRING TENSION ARM

The pressure arm controls the amount of force the drive
rolls exert on the wire. Proper adjustment of both pres-
sure arm gives the best welding performance. For best
results, set both pressure arms to the same value.
Set the pressure arm as follows (See Figure B.2a):
Aluminum wires
Cored wires
Steel, Stainless wires
Figure B.2a
CORED WIRES
1
3 2
OUTERSHIELD
METALSHIELD
5
INNERS HIELD
B-5
(Figure B.2)
2 STEP/TRIGGER
INTERLOCK
SWITCH
SPINDLE
BRAKE
between 1 and 3
between 3 and 4
between 4 and 6
SOLID WIRES
ALUMINUM
4
STEEL
6
STAINLE SS

Advertisement