Thermal Protector; Troubleshooting; Warranty - Bissell Little Green HydroSteam 3532 Series Manual

Portable carpet and upholstery cleaner
Table of Contents

Advertisement

Thermal Protector

An internal thermal protector has been designed into your machine to protect it from overheating.
When the thermal protector activates, the main motor will stop operating. If this happens, proceed as
follows:
1. Turn machine OFF and unplug from electrical outlet.
2. Let the motor cool for approximately 30 minutes. The thermal protector will automatically reset,
and cleaning may continue once plugged back in.
Note: If the thermal protector continues to activate after following the above steps, your machine
may need servicing. Call BISSELL® Consumer Care or visit the website.

Troubleshooting

Below are some of the issues you may run into. If you don't see the issue you're experiencing
below, visit support.BISSELL.com.
Problem
Reduced/no
spray
Reduced/loss
of suction
Machine leaks
No/low steam.
Steam ready light
not illuminated
after two minutes.
Note: Any other servicing should be performed by an authorized service representative.

Warranty

Limited 3-year warranty, may vary by state. Visit support.BISSELL.com or call 1-800-237-7691 for
complete warranty information.
Possible Cause
Clean water tank may be empty.
Clean water tank may not be
seated properly.
Spray tip may be clogged/dirty.
Dirty tank may be full.
Red filter under dirty tank may
be clogged.
Dirty tank may not be correctly
seated.
Dirty tank lid may not be
correctly seated.
Tool or hose may be clogged
with hair/fibers/etc.
From bottom: Dirty tank has
been filled beyond the "Max"
line with water or foam.
From hose/tool: Water remains
in hose after turning off.
Clean water tank may be empty.
Machine not pre-heated.
Water sprays instead of steam.
Thermal Protector on heater has
tripped.
Remedies
Refill tank.
Fully seat tank until it clicks into place.
Clean spray tip.
Empty dirty tank.
Remove any debris from the red filter.
Ensure there are no obstructions preventing the
dirty tank from fully being seated in its recess.
Ensure the lid is fully seated in the dirty tank
and the handle fully locks the lid into place.
Remove any clogs.
Do not allow machine to collect liquid past
the "max" line. Ensure only Bissell portable
deep cleaner formulas are used, at the correct
concentrations, to prevent excessive foaming.
Run machine for several seconds after stopping
suction to ensure water is sucked into dirty tank.
Refill tank.
Wait 30 seconds for "steam ready" indicator
light to turn on.
This is normal; a small amount of water
condensate forms in the steam lines when
steam is not used. Continue to hold the trigger
and steam will come out within 5-10 seconds.
Please visit an authorized service center.