Sony TRINITRON KV-29C3A Service Manual page 22

Table of Contents

Advertisement

KV-29C3
@By rotating the V.STAT magnet clockwise, the red, green
and blue dots move as shown below.
@By opening orclosing the V.STAT magnet, the red, green and
blue dots move as shown below.
¢ Ifthe blue dot does not coincide with the red and green points,
correct the points by using the BMC (Hexapole) magnet.
®Correction for HMC (horizontal mis-convergence) and VMC
(vertical mis-convergence) by using the BMC (Hexapole)
magnet.
@HMC correction by BMC (Hexapole) magnet and movement
of the electronic beam.
HMC
correction(A)
HMC correction(B)
A>BR
GB
Oo
OO
s
X\
I)
v
A=BRGB
Ooo 0
(ese! eae |
@VMC correction by BMC (Hexapole) magnet and movement
of the electronic beam.
VMC tC
VMC
correction(B)
fd
C<D
C>D
=
cPoOR
he
OR
aes
OGe_l
OB
OB
oB
OB
Layout of each control
Purity magnet
BMC (Hexapole) magnet
V.STAT convergence magnet
Y-splitting axis correction magnet
RAW
=
|
| Pi2
7771
Fig.3-5
2. If you are unable to adjust the corner convergence properly,
correct them with the use of permalloys.
a-d: screen-corner
convergence defect
Permalloy Assy
'an
X-4387-214-1
ya
tye
adjustment with permalloy
— 99 —