Heat run time
Operating
temperature range
Storage
temperature range
Withstand voltage
Case construction
Case material
Wetted part material
Mounting clamp
material(Option)
Cable
Weight
EMC Directive *3
*1 Factory default
*2 For horizontal mounting only (GC31-3□4). Vertical mounting (GC31-1□4) is not
available.
*3 Please connect this unit to indoor distribution network which is free from any
overvoltage such as thunder, etc.
Analog output
1 - 5 VDC, 1 output
Output accuracy
Response
Resolution
Load resistance
More than 15 min.
-10 to 50 ℃, 35 to 85 %RH (No condensation / freezing allowed)
-20 to 60 ℃, 35 to 85 %RH (No condensation / freezing allowed)
300 VAC, 1 min.
IP 40 (For interior use)
Front case part
Rear case part
Sensor part
Fitting part
Key / L-shaped bracket
Panel adaptor
Length
2 m
Conductor
:0.18 sq (7/0.18), Coated outer diameter : 0.86(㎜)
Sheath
:Outer diameter : 4(㎜), Material: PVC
Approx. 120g (Including 2 m cable)
Applicable directive 89/336/EEC
Applicable standards
EN61326:1997/A1:1998/A2:2001/A3:2003
TY-GC31-004A
: ±1.5 %F.S. (for indication)
:Less than 50 ms
:Approx. 30 mV DC
:10 kΩ min.
: PC/ABS
: ADC 12
: SUS 630 (17-4 PH)
: SUS 304
: SPCC (t1.6)
: PC/ABS *2
4/24
Rev.B