Electrical Connections - Monogram ZHP365ETVSS Installation Instructions Manual

30” and 36” professional induction ranges
Hide thumbs Also See for ZHP365ETVSS:
Table of Contents

Advertisement

Available languages

Available languages

4

ELECTRICAL CONNECTIONS

WARNING
This appliance must be properly
grounded.
WARNING
All new constructions, mobile
homes, recreational vehicles and installations where
local codes do not allow grounding through neutral,
require a 4-conductor UL listed range cord.
WARNING
To prevent fire or shock, do not use
an extension cord with this appliance.
WARNING
To prevent shock, remove house
fuse or open circuit breaker before beginning
installation.
We recommend you have the electrical wiring and
hookup of your range connected by a qualified
electrician. After installation, have the electrician show
you how to disconnect power from the range.
You must use a single-phase, 120/240 VAC, 60 hertz
electrical system. If you connect to aluminum wiring,
properly installed connectors approved for use with
aluminum wiring must be used.
Effective January 1, 1996, the National Electrical
Code requires that new construction (not existing)
utilize a 4-conductor connection to an electric range.
When installing an electric range in new construction,
mobile home, recreational vehicle, or an area where
local codes prohibit grounding through the neutral
conductor, refer to the section on four-conductor
branch circuit connections.
Check with your local utilities for electrical codes which
apply in your area. Failure to wire your oven according
to governing codes could result in a hazardous
condition. If there are no local codes, your oven must
be wired and fused to meet the National Electrical
Code, NFPA No. 70 – latest edition, available from the
National Fire Protection Association.
This appliance must be supplied with the proper
voltage and frequency, and connected to an individual,
properly grounded, branch circuit protected by a circuit
breaker or time-delay fuse. The breaker or fuse should
be at a minimum 40 amp for the 30" induction range
and a minimum 50 amp the 36" induction range (larger
amp breaker/fuse acceptable).
Use only a 3-conductor or a 4-conductor UL listed
range cord. These cords may be provided with ring
terminals on wire and a strain relief device.
31-2001170 Rev 0
Installation
4
ELECTRICAL CONNECTIONS (Cont.)
All 30" and 36' induction ranges are supplied with a
50 amp UL listed cord (4 wire, NEMA 14-50P).
NOTE: Use of automatic, wireless or wired external
switches that shut off power to the appliances, are not
recommended for this product.
The access
plate is on
the back of
the range.
5
4-WIRE POWER CORD
INSTALLATION
NOTE: A 4-wire cord is connected to the range at the
factory. Use the following steps to change an existing
installation from a 3-wire cord (not included with the
new range) back to a 4-wire cord.
WARNING
must be connected to the neutral terminal located
in the lower center of the terminal block. The power
leads must be connected to the lower left and the
lower right terminals of the terminal block. The 4th
grounding lead must be connected to the frame of the
range with the ground plate and the ground screw.
Remove the 3 lower terminal screws from the
terminal block. Remove the ground screw and
ground plate and retain them.
Remove the ground strap.
DO NOT DISCARD THE GROUND STRAP OR
ANY SCREWS.
Insert the one ground screw into the power cord
ground wire terminal ring, through the ground plate
and into the frame of the range.
The neutral wire of the supply circuit
11

Advertisement

Table of Contents
loading

Table of Contents