Aktakom APS-7306 User Manual

Programmable dc power supply

Advertisement

Quick Links

User's manual
PROGRAMMABLE DC POWER SUPPLY
APS-7306
Thank you for choosing AKTAKOM Power Supply.
www.tmatlantic.com

Advertisement

Table of Contents
loading

Summary of Contents for Aktakom APS-7306

  • Page 1 User’s manual PROGRAMMABLE DC POWER SUPPLY APS-7306 Thank you for choosing AKTAKOM Power Supply. www.tmatlantic.com...
  • Page 2: Brief Product Introduction

    Power Supply APS-7306 is a highly accurate, DC-regulated power supply with an adjustable output. This output can be used for constant voltage (C.V.) and constant current (C.C.).
  • Page 3: Technical Parameters

    Model APS-7306 Output voltage 0-30V Output current 0-5A Output power 150W TECHNICAL PARAMETERS These parameters are tested under 25±5°C and after 2s power on. Power effect: CV≤0.01%+3mV (AC±5%) Load effect: CV≤0.01%+2mV Ripple and noise: ≤2.0mVrms Output accuracy: 0.5%+20mV 0.5%+10mA Read-back accuracy: V:...
  • Page 4 DIAGRAMS OF PANELS Front Panel 1. Power: on/off button 2. Off/On: output on/off 3. MEN: memory save 4. M1-M3: memory recall 5. Voltage/Current: select between voltage or current 6. OCP: over current protection 7. CC indicator: constant current mode 8. CV indicator: constant voltage mode 9.
  • Page 5: Operation

    OPERATION Switching the Power Supply On or Off 1. Connect the included power cord to the back of the device [16] and plug the other end into a suitable, earthed power socket. Always connect the device to an earthed power socket. Press the Power button [1] to switch the power supply on.
  • Page 6 o For use in constant voltage mode: this is the desired current limit. o For use in constant current mode: this is the desired constant current. o If you enable overcurrent protection, the output switches off automatically if the current exceeds this value. 4.
  • Page 7 Applying Voltage to the Load 1. Press the Off/On key [1] to apply the voltage to the load. The OUT [2] and C.V. indicators [8] light. The power supply works in constant voltage (CV) mode; the display now shows the actual output voltage and current.
  • Page 8 REMOTE CONTROL VIA PC Introduction The Aktakom Power Manager Express application is designed to manage AKTAKOM APS-7306 power supplies 2. Getting Started 2.1 Minimum computer requirements Computer used for the device work should meet the following minimal requirements: - USB-port;...
  • Page 9: Installation

    All necessary files are located in the program working directory, for example: C:\Program Files\AKTAKOM\AKTAKOM Power Manager Express\Driver INSTALLATION: ### Prompted install ### If Windows prompts you to install a driver for a CP210x device (for example, if you plug a CP210x into your computer): 1.
  • Page 10 Button "Turn OFF when closed" - enables/disables the mode of automatic switching off of the outputs of the device at the end of the program. "News" button shows or hides Aktakom news feed. "Info" button displays the information about the program and connected device.
  • Page 11 - by voltage or current. Remarks The APS-7306 device in the basic configuration has some features of operation: - there is no command to turn off remote operation - to switch to local control, turn off and then turn on the power supply of the device.
  • Page 12: Product Registration

    PRODUCT REGISTRATION Please register on http://www.tmatlantic.com before the software installation and the device configuration for remote control mode operation And then download the program installer following the recommendations on the web site www.tmatlantic.com. For detailed information on the operating modes of the instrument, please refer to the User's Manual.