Model
Output voltage
Output current
Output power

TECHNICAL PARAMETERS

These parameters are tested under 25±5°C and after 2s power on.
Power effect:
Load effect:
Ripple and noise:
Output accuracy:
Read-back accuracy: V:
Types of protection: over current, over voltage, over temperature
Working environment:
Humidity:
ATTENTION
Kindly use the rated input voltage;
Never operate at a high temperature and the cooling exit
mustn't be blocked;
Please make the fuse with rated parameters equipped.
3
APS-7306
0-30V
0-5A
150W
CV≤0.01%+3mV (AC±5%)
CV≤0.01%+2mV
≤2.0mVrms
V:
0.5%+20mV
I:
0.5%+10mA
10mV
I:
1mA
0∼40°C
less than 80%
www.tmatlantic.com