Error Codes
If an error is detected, the controller will display an error code. Refer to the following table for
descriptions and solutions:
ERROR
CODE
ER1
ER2
ER3
ER4
ER5
Probe Communication Failure
ER9
TM
ER1
Firebox Theromocouple Sensor Failure
ERROR DESCRIPTION
Grill Probe (RTD) Sensor
Failure
Ignition Failure
High Temperature Limit
Protection
Low Temperature Limit
Network Communication
Failure
P1
P2
Check wiring connection from RTD to the controller. If wire
terminals are secure, RTD replacement may be required.
• Inspect pellet feed system; verify pellets reach fire pot; restart.
• Remove excess ash and/or pellet build-up in fire pot; restart.
• Check ambient outdoor temperature. If RTD is too cold, the
pellets may ignite but not get the RTD warm enough within the
programmed time.
• Allow grill to cool. Inspect cause of excessive temperature
(grease fire, food fire, excess pellets).
• Clean grease or food residue. Clean fire pot. Restart grill.
• Close lid (if grilling for long time with lid open). Restart grill.
• Check pellet feed system and ensure pellets reach fire pot.
Clean fire pot if needed. Restart grill.
Check meat probe connection at each port where attached.
Remove mini plug and re-insert. If error continues, replace meat
probe.
Check Wi-Fi network is operating properly and the grill is in range
of a strong network signal. Allow time for proper connection
to be established. If it does not re-connect, reboot the grill.
Sometimes rebooting the network server/router is required to
issue new IP addresses (due to quantity of connected devices).
NOTE:
To dismiss an error
code, reboot the
controller by turning
it off for a few
seconds.
Touch "info"
icon to display
P3
solution.