3.3 Accessories: Actuator (optional)

The PAW actuator for weather-compensated control is available as an accessory.
For mixing valves with flow on the left, the scale must be turned by 180°.
for mixing valve with flow on the right
12
for mixing valve with flow on the left
Assembly of the actuator - flow on the right:
If the PAW actuator has been purchased as an optional
accessory, the mixing valve contains a metal plate. To
mount the PAW actuator on the mixing valve, proceed as
follows:
1. Turn the rotary knob of the mixing valve into
Position 0.
2. Set the actuator to manual mode by turning the
selector switch.
3. Turn the rotary knob of the actuator to the left to the
position shown on the adjacent figure.
4. Mount the rotation lock / the stop bolt in the left
opening of the metal plate. The actuator is fixed on a
stop bolt.
5. Put the PAW actuator on the rotary knob of the mixing
valve and mount the actuator on the stop bolts. The
PAW actuator must be mounted in a horizontal
position.
6. Set the actuator to automatic mode.