Permanent Wiring Installation - Toyostove Laser 30 Type B Installation And Operation Instructions Manual

Laser clean heating system/vented heater
Hide thumbs Also See for Laser 30 Type B:
Table of Contents

Advertisement

WARNING:
MAKE SURE POWER SUPPLY CORD IS DISCONNECTED TO AVOID ANY ELECTRIC SHOCK
BEFORE SERVICING. ELECTRIC SHOCK MAY CAUSE SERIOUS INJURY.
INSTALLATION SHOULD BE CONDUCTED BY A LICENSED ELECTRICIAN.
Step 1.
Disconnect power supply cord
from power source.
Remove three (3) screws and
control box cover on the back
of the heater.
Step 2.
Disconnect ground wire (green
wire) from the power supply
cord bracket.
Step 3.
Disconnect two power supply
wires from right side of the ter-
minal.
NOTE: Emergency power supply and use of 12V DC batteries and an inverter. Consult your dealer
before attempting to use a battery/inverter system to provide power for your Laser heater.
These units require true sine wave power for proper long-term operation. Some modified sine
wave inverters can be used to provide short-term emergency power but some types of modi-
fied sine wave inverters will cause damage to the electrical components of the heater. Several
inverter manufacturers offer true sine wave inverters which should operate the unit without any
problems if properly sized and configured. If you have any questions about appropriate power
supply, consult your authorized TOYOSTOVE dealer.

PERMANENT WIRING INSTALLATION

Step 4.
Squeeze strain relief with the
adjustable pliers to remove
plastic bushing from the pow-
er supply cord bracket.
Remove the power supply
cord.
Step 5.
Insert the power supply cable
from junction box and connect
ground wire to the power sup-
ply cord bracket and power
wires to the terminals.
Step 6.
Affix the control box cover to
the heater and insert screws.
28

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Toyostove laser 30 type dLaser 30

Table of Contents