Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K Gas Powered Convection Ovens NOTICE This manual is for a certified service technician and should not be used by those who are not properly trained. This manual cannot cover all possible conditions that may occur and is not ¾"...
Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K Contents Troubleshooting ......... .3 Part Testing Main Power Switch .
Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K Troubleshooting Problem Possible Solution Ensure gas supply is turn on. Ensure gas supply is at the correct pressure. Ensure unit is plugged in and has correct voltage. Ensure unit power switch is on.
Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K Part Testing CAUTION: Components can be HOT Main Power Switch Check for continuity, disconnect wires from rear terminals on switch, check between middle and lower terminals when 'ON'. If none found, replace switch. If found move to next check below.
Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K Fan Speed Switch Disconnect wires from rear of switch. Check continuity between middle and top terminals and switch in 'HI' position. Then check continuity between middle and lower terminals and switch is in 'LOW' position. If continuity is not found in both switch positions, replace switch.
Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K Timer Fig. 8 Disconnect wires from rear of timer. Turn timer knob to 0 minutes, check for continuity across terminals on rear of switch. If none is found, replace timer. (Fig. 9) Turn knob to between 1 and 60 minutes, check that no continuity is found.
Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K Transformer Fig. 13 Check for 120 volts at terminals (Fig. 13A). Check for 24 volts at terminals (Fig. 13B). If voltage is not correct, replace. 24 volts goes to thermostat, 'HEAT ON' lamp and gas solenoid valve.
Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K Door Switch Disconnect wires from rear of switch. Check continuity between terminals when switch lever is in 'CLOSED', position. If continuity is not found in 'CLOSED' position, replace switch. If found, see below for more testing.
Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K Surface Igniter Visually check that surface igniter 'glows' when thermostat first calls for heat. Check with unit 'ON' and thermostat calling for heat (Fig. 20 & 21). Check for 120 volts from S2 connection on ignition module to Neutral wire on back of unit (Fig.
Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K Gas Solenoid Valve Ensure gas is being supplied to unit. Check Fig. 26 incoming pressure using manometer on inlet side of valve. Check if solenoid valve is getting 24 VAC. If no voltage, check ignition module. If voltage is found, and still no gas is coming through, replace gas valve (Fig.
Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K Part Replacement Fig. 29 Fig. 30 Fig. 31 Fan Motor Turn unit off, disconnect gas and electrical connections. Remove right side panel to disconnect motor wires from inside plug (Fig. 29). Remove wiring from rear of unit (Fig. 30 & 31).
Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K ALL GAS CONNECTIONS MUST BE CHECKED FOR LEAKS Internal Gas Regulator Turn unit off. Disconnect gas and electrical connections. Fig. 41 Remove hex bolts holding right side on with an 8mm socket.
Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K Door Latch Removal Turn off power switch and gas supply to unit. Fig. 44 Disconnect unit from power supply. Open front door(s) on unit to access latch. Remove 2 Phillips head screws and pull latch from top of door (Fig.
Page 17
Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K Control Panel Assembly Item # Description Part # Item # Description Part # Buzzer 351100086 Thermostat 351030169 Power Switch 351080141 Heat Light 351130140 Ignition Module 351150304 Fan Speed Switch 351080141 Timer 351120028...
Page 18
Service Manual 351FGC100(L/N) | 351FGC200(L/N)K 351FGC100DD(L/N) | 351FGC200DD(L/N)K Door Assembly Item # Description Part # Door Latch 35165002016 Door Assembly - Left 35165002014 Door Assembly - Right 35165002011 www.cookingperformancegroup.com...