Terminal Board And Grounding; Terminal Boxes, End Shields, Grounding Conductors, Sheet Metal Fan Covers; Cable Glands - Siemens SIMOTICS A 1FU9 Operating Instructions Manual

Synchronous motors
Table of Contents

Advertisement

Technical data
A.1 Tightening torques
A.1.2

Terminal board and grounding

Table A-2
Tightening torques for electrical connections on the terminal board and grounding
Thread ∅
M3.5
min.
0.8
Nm
max.
1.2
A.1.3

Terminal boxes, end shields, grounding conductors, sheet metal fan covers

If no other tightening torques are specified, then the values in the following table apply.
Table A-3
Tightening torques for screws on the terminal box, end shields, screw-type grounding conductor connections
Thread ∅
M3.5
Nm
min.
0.8
max.
1.2
Table A-4
Tightening torques for self-tapping screws on the terminal box, end shields, screw-type grounding conductor
connections, sheet metal fan covers
Thread ∅
Nm
A.1.3.1

Cable glands

Note
Avoid damaging the cable jacket.
Adapt the tightening torques to the cable jacket materials.
134
M4
M5
0.8
1.8
1.2
2.5
M4
M5
M6
2
3.5
6
3
5
9
min
max
M6
M8
2.7
5.5
4
8
M8
M10
16
28
24
42
M 4
M 5
4
7.5
5
9.5
Operating Instructions, 10/2023, A5E46712792A
M10
M12
9
14
13
20
M12
M16
46
110
70
165
M 6
12.5
15.5
M16
27
40
M20
225
340
1FU9

Advertisement

Table of Contents
loading

Table of Contents