▶ Do not step on the hob or the work sur-
face.
The filter cover may swing out.
▶ Open the filter cover slowly.
▶ Take hold of the filter cover after opening
until it no longer swings out.
▶ Close the filter cover slowly.
Risk of injury when opening and closing the
hinges.
▶ Keep your hands away from the hinges.
WARNING ‒ Risk of electric shock!
Sharp-edged components inside the appli-
ance may damage the connecting cable.
▶ Do not kink or trap the connecting cable.
If the appliance or the power cord is dam-
aged, this is dangerous.
▶ Never operate a damaged appliance.
▶ Never pull on the power cord to unplug the
appliance. Always unplug the appliance at
the mains.
▶ If the appliance or the power cord is dam-
aged, immediately unplug the power cord
or switch off the fuse in the fuse box.
▶ Call Customer Service. → Page 14
▶ Repairs to the appliance should only be
carried out by trained specialist staff.
Incorrect repairs are dangerous.
▶ Repairs to the appliance should only be
carried out by trained specialist staff.
▶ Only use genuine spare parts when repair-
ing the appliance.
▶ If the power cord of this appliance is dam-
aged, it must be replaced by trained spe-
cialist staff.
Improper installation is dangerous.
▶ Connect and operate the appliance only in
accordance with the specifications on the
rating plate.
▶ Connect the appliance to a power supply
with alternating current only via a properly
installed socket with earthing.
▶ The protective conductor system of the do-
mestic electrical installation must be prop-
erly installed.
▶ Never equip the appliance with an external
switching device, e.g. a timer or remote
control.
▶ When the appliance is installed, the mains
plug of the power cord must be freely ac-
cessible. If free access is not possible, an
all-pole isolating switch must be installed in
the permanent electrical installation accord-
18
ing to the conditions of Overvoltage Cat-
egory III and according to the installation
regulations.
▶ When installing the appliance, check that
the power cable is not trapped or dam-
aged.
17.5 Information on the installation situation
¡ Install this appliance on the kitchen ceiling or a
stable suspended ceiling.
¡ To install additional special accessory parts, ob-
serve the enclosed installation instructions.
¡ The appliance finds it more difficult to draw in the
cooking vapours the further away they are from the
hob. Therefore maintain a distance of at least
700 mm and no more than 1500 mm.
17.6 Instructions for the exhaust air pipe
The appliance manufacturer does not provide any war-
ranty for faults attributable to the pipeline.
¡ Use a short, straight exhaust air pipe with as large a
pipe diameter as possible.
¡ Long, rough exhaust air pipes, many pipe bends or
small pipe diameters reduce the suction power and
increase the fan noise.
¡ Use an exhaust pipe that is made of non-combust-
ible material.
¡ To prevent condensate from returning, fit the ex-
haust pipe with a 1° gradient from the appliance.
Flat ducts
Use flat ducts with an inner cross-section that corres-
ponds to the diameter of the round pipes:
¡ Diameter of 150 mm corresponds to ap-
prox. 177 cm².
¡ Diameter of 120 mm corresponds to ap-
prox. 113 cm².
¡ Use sealing strips for different pipe diameters.
¡ Do not use any flat ducts with sharp bends.
Round pipes
Use round pipes with an inner diameter of 150 mm (re-
commended) or at least 120 mm.
17.7 Instructions for the electrical
connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
WARNING ‒ Risk of electric shock!
It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.
The mains plug for the mains power cable must be
easily accessible after the appliance is installed.
If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.
The permanent electrical installation must only be
wired by a professional electrician. We recommend

Advertisement

Table of Contents
loading

This manual is also suitable for:

I25cbs8w0 seriesI97cps8w5 seriesI97cqs9s5

Table of Contents