Download Print this page

KERN 20K10 Operating Instructions page 3

Hanging scale

Advertisement

7.2
Weighing units switch-over
Using the Unit-key you can switch over the display between N,
lb and kg. The
marks the active setting.
7.3
Taring
• Switch on the balance using the ON/OFF/TARE-key and wait
for the „0" display. Suspend the tare load and press the
ON/OFF/TARE -key.
• The balance display jumps to „0.0". The weight of the tare
load is internally stored. The material to be weighed can now
be filled in the tare vessel and the weighing value can be
read.
7.4
Functions
With help of the Hold-key the following functions can be acti-
vated:
Setting
Function
H1
Data-Hold function 1
Weighing value frozen for 5 sec. after press-
ing the Hold-key
H2
Data-Hold function 2
The weighing value will be frozen after press-
ing the Hold-key until another key is actuated
H3
Data-Hold function 3
The weighing value is automatically frozen
for 5 sec.
H4
Data-Hold function 4
The weighing value is automatically frozen
after reaching a stable value until a key will
be actuated
H5
Animal weighing function
H6
Peak value function
7.4.1
Data-Hold function
With the Data-Hold function the weighing values in the display
can be fixly displayed for a longer time. According to the using
range you can select between 4 settings (H1 – H4).
Switch on the balance, keep the HOLD-key pressed until
the current setting „Hx" (H1 – H6) appears.
Actuate the ON/OFF/TARE-key until the desired setting
(H1-H4) appears.
Use the HOLD-key to confirm your selection
Suspend the material to be weighed
The weighing value is displayed depending on your set-
tings (H1 – H4) (see table chap. 7.4), symbolised by the
[ ] top left.
7.4.2
Animal weighing function
This function is suitable for busy weighing procedures. The
result is a mean value formed by 16 weighing values which is
found out within 3 seconds.
Switch on the balance, keep the HOLD-key pressed until
the current setting „Hx" (H1 – H6) appears.
Press the ON/OFF/TARE-key until „H5" appears.
Use the HOLD-key to confirm your selection
Suspend the material to be weighed
Press the HOLD-key, the display counts reverse from
3 -1. The calculated mean value is indicated, symbolised
by the [ ] top left.
For further measurements press the ON/OFF/TARE-key
before
7.4.3
Peak value function
This function displays the highest load value (peak value) of a
weighing.
Measuring frequency: 200ms
8
Caution:
Never exceed the maximum permitted load of the
peak value on the balance (!!Danger of breaking!!).
Switch on the balance, keep the HOLD-key pressed until
the current setting „Hx" (H1 – H6) appears.
Press the ON/OFF/TARE-key until „H6" appears.
Use the HOLD-key to confirm your selection
Suspend the material to be weighed
The peak value appears for a short time, symbolised by
the [ ] top left. The balance returns automatically to zero
and is ready for further measurement.
8
Service, maintenance, disposal
8.1
Cleaning
Please do not use aggressive cleaning agents (solvents or
similar agents), but a cloth dampened with mild soap suds.
Ensure that no liquid penetrates into the device and wipe with a
dry soft cloth.
8.2
Service, maintenance
The appliance may only be opened by trained service techni-
cians who are authorized by KERN.
8.3
Disposal
Disposal of packaging and appliance must be carried out by
operator according to valid national or regional law of the loca-
tion where the appliance is used.
9
Instant help
In case of a fault in the program sequence, the balance should
be shortly switched off. The weighing process must then be
restarted from the beginning.
Fault
Possible cause
Display weight
The balance is not switched on.
does not glow. •
Batteries are inserted incorrectly or empty
No batteries inserted.
Displayed
Draught/air movement
weight is per-
Vibrations on the supension of the balance
manently
changing
Electromagnetic fields / static charging
(choose different location/switch off inter-
fering device if possible)
Weighing
The display of the balance is not at zero
result obvi-
• Great fluctuations in temperature.
ously incorrect
• Electromagnetic fields / static charging
(choose different location/switch off inter-
fering device if possible)
Should other error messages occur, switch balance off and
then on again. If the error message remains inform manufac-
turer.
HCB-BA-e-0732

Advertisement

loading

This manual is also suitable for:

20k5050k2050k10099k50100k200200k100 ... Show all