W&T 57753 Manual

Sip ring switch

Advertisement

Quick Links

Manual
Installation, Startup and Application
SIP Ring Switch
valid for:
#57753
SIP Ring Switch 4xOut
Release 1.68 September 2023

Advertisement

Table of Contents
loading

Summary of Contents for W&T 57753

  • Page 1 Manual Installation, Startup and Application SIP Ring Switch valid for: #57753 SIP Ring Switch 4xOut Release 1.68 September 2023...
  • Page 2 © 10/2021 by Wiesemann und Theis GmbH Microsoft, MS-DOS, Windows, Winsock and Visual Basic are registered trademarks of the Microsoft Corporation. Subject to error and alteration: Since it is posssible that we make mistakes, you mustn’t use any of our statements without verification.
  • Page 3: Table Of Contents

    Conent Content 1. Legal notices ..............5 Warning notice system ..................5 Qualified personnel .................... 5 Disposal ......................6 Symbols on the product ..................6 2. Safety notices ..............7 General notices ....................7 Intended use ....................... 7 Electrical safety ....................7 EMC 8 Batteries ......................
  • Page 4 Conent 5. Installation and wiring ............14 Montage #57753 ....................14 Terminal assignment 57753 ................14 Wiring #57753 ....................15 Network connection ..................16 6. Initial start-up ..............17 Assigning the IP address ................. 17 Changing the set IP parameters ..............18 7.
  • Page 5: Legal Notices

    Legal notices 1. Legal notices Warning notice system This manual contains notices that must be observed for your personal safety as well as to prevent damage to equipment. The notices are emphasized using a war- ning sign. Depending on the hazard level the warning notices are shown in decrea- sing severity as follows.
  • Page 6: Disposal

    Legal notices ly the safety and warning notices contained therein. Qualified personnel are defined as those who are qualified by their training and experience to recognize risks when handling the described products and to avoid possible hazards. Disposal Electronic equipment may not be disposed of with normal waste, but rather must be brought to a proper electrical scrap processing facility.
  • Page 7: Safety Notices

    Safety notices 2. Safety notices General notices This manual is intended for the installer of the SIP Ring Switch described in the ma- nual and must be read and understood before starting work. The devices are to be installed and put in operation only by qualified personnel. Intended use 1DANGER The SIP Ring Switch manufactured by Wiesemann &...
  • Page 8: Emc

    Safety notices When installing be sure that no stray wires stick out through the ventilation slit of the SIP Ring Switch into the housing. Ensure that no individual wires stand off from leads, that the lead is fully contained in the clamp and that the screws are tightly fastened.
  • Page 9 Safety notices #57753 Use a pointed object to press on the latching hooks on the side of the housing and at the same time pull the bottom of the housing out of the top shell. Then remove the stack of PCBs downwards from the housing.
  • Page 10: Quick Startup

    Quick Startup 3. Quick Startup Network connection Supply voltage #57753 12 - 24V Inputs/Outputs 12 - 24V DC Inp. = ON Outp. = ON 150mA + 12-48V max. 4x500mA Out Output Load Outputs: max. 4x500mA For the first test leave the outputs unwired.
  • Page 11: Product Introduction

    Product introduction 4. Product introduction Hardware #57753 - SIP Ring Switch 4xOut Network interface: RJ45 10/100BaseT / PoE Power: Screw terminal 12 … 24V DC Outputs: 4 output channels Output 12 ... 24V DC current driving max. 500mA Network security All available network services are configurable and must first be enabled by the administrator.
  • Page 12: Application And Access Possibilities

    Product introduction Administrator After logging in with a password the administrator has unrestricted configuration and access rights. By default no passwords are assigned for the SIP Ring Switch. Simply click on the Login button. After login the navigation tree on the left side can be used to open the enabled con- figuration areas.
  • Page 13: Actions

    Product introduction Individual applications The SIP Ring Switch offers TCP socket access from your own applications. The SIP Ring Switch supports addressing using command strings. With the support of HTTP requests your own web applications (e.g. with PHP or JavaScript) can also access the SIP Ring Switch.
  • Page 14: Installation And Wiring

    For mechanical fixation, the SIP Ring Switch should be snapped onto a 35mm top-hat rail according to DIN EN 50022. In doing so, the Web IO takes up 45mm in width. Terminal assignment 57753 Terminal Description / Function + Vcc - Device supply 12-24V 150mA@24V...
  • Page 15: Wiring #57753

    LED Test shown on Reset Error Reset ______________ URL: SIP Ring Switch #57753 Digital, 4xOut With a typical industrial power supply of 24V, the SIP Ring Switch draws approxima- tely 100mA of current. 1NOTE IO channels that are configured as outputs are also supplied via VDD. The loads to...
  • Page 16: Network Connection

    Input/Output Mode Check Error and LED Test shown on Reset Reset ______________ URL: SIP Ring Switch #57753 Digital, 4xOut Network connection A shielded standard ethernet patch cable (min. CAT5) with RJ45 plugs can be used for the network connection. Link...
  • Page 17: Initial Start-Up

    Initial start-up 6. Initial start-up After the SIP Ring Switch has been properly installed and wired, the power supply can be switched on. All three status LEDs should light up briefly. After approx. 5 seconds only the Power LED should remain on. The Status LED may flash. If the network connection is working, the green LED in the network socket signals an active link.
  • Page 18: Changing The Set Ip Parameters

    Initial start-up WuTility suggests the network parameters (subnet mask, gateway, DNS server) that also apply to the PC. If you want the SIP Ring Switch to work in the same subnet as the PC, you only need to adjust the IP address. If you select Address range >...
  • Page 19: Basic Settings

    Basic settings 7. Basic settings The further configuration of the SIP Ring Switch is done using a web browser. Enter the IP address of the Web IO in the browser command line. In the navigation tree, click Login and choose Administrator as user. By default, no password is assigned and a click on the login button is sufficient to configure the SIP Ring Switch with administrator rights.
  • Page 20: Date / Time

    Basic settings This is repeated as long as the output is active. Date / Time In the Date / Time section you can define whether a periodical adjustment with a time server should take place. In addition, date and time can also be set manually. The configuration of a time zone and the daylight saving time can also be done here.
  • Page 21: Certificates

    Basic settings Certificates Protocols such as HTTPS are based on the TLS protocol. The encryption of the communication and the authentication of the communication partners is realized via certificates. The Web IO identifies itself ex works with a self-signed certificate. Many applica- tions consider such certificates to be a security risk.
  • Page 22: Basic Applications

    Basic applications 8. Basic applications The SIP Ring Switch has several communication paths and supports some standard protocols. We recommend that you only enable the communication paths that are actually required in your application. In this way, you limit the possibility of unwan- ted third-party access and manipulation.
  • Page 23 Basic applications Extension inventory This is where you define which extensions or phone numbers the SIP Ring Switch represents. New extensions are created via the Add button. Afterwards the following parameters have to be specified: Extension Enter here an extension number which represent the SIP Ring Switch Alias Context-sensitive name for the extension, e.g.
  • Page 24: Browser Access

    Basic applications After clicking the Add button, a new participant can be created via the mask that appears. Caller Enter the extension or number of an accepted caller here. To include entire phone number ranges in the list, „*“ can be used as a wildcard. Examples: every caller is accepted extensions 210 - 219 are accepted...
  • Page 25 Basic applications HTTP or HTTPS Ex works, the browser access is enabled for HTTP via port 80. To switch access to HTTPS or change the port, select Basic Settings „ Network in the navigation tree and then Protocol in the Access for web services area. All other settings concerning the display in the browser can be made under Web pages.
  • Page 26: Sending Email

    SIP Ring Switch. The manual for your SIP Ring Switch can be found on the respective Web data sheet page at www.WuT.de/article number, e.g. www.wut.de/57753 Sending email A few basic settings are necessary in order to send email messages.
  • Page 27 Basic applications Select E-mail message as the action. In the corresponding input mask you have the possibility to write an individual e-mail message. Use the placeholders described below, which are replaced by the current IO states, counter values, etc. when the e-mail is sent.
  • Page 28: Actions

    Integration into existing systems 9. Actions With the action principle, the SIP Ring Switch offers the possibility to react individu- ally to certain events such as incoming calls, changes in the switching state of the outputs or device restarts. As a reaction, the SIP Ring Switch can switch outputs, send e-mails, HTTP requests or TCP messages and write log data to a file via FTP.
  • Page 29 Integration into existing systems Valid characters: represents all valid values in the respective input field (e.g. every minute or every hour) specifies a range of from…to (e.g. weekday “2-4” stands for Tuesday to Thursday, whereas entering “*” triggers the timer on all weekdays). Interval within the specified range (e.g.
  • Page 30: Actions

    Integration into existing systems Actions Switching outputs When switching outputs the SIP Ring Switch differentiates between switching its own outputs or switching the outputs on another SIP Ring Switch. Switching the own outputs The outputs can be switched to ON or OFF. Another possibility is to toggle the exist- ing state.
  • Page 31 Integration into existing systems The outputs must be set in Output Mode Menu. Actions with text messages For the actions that allow the sending of alarm, message and other texts, placehol- ders can be used within the text that are replaced with actual contents, such as IO states, time, etc., when an action is executed.
  • Page 32 Integration into existing systems HTTP request Another possible action is to send an HTTP request as required by some devices, such as cameras, to trigger certain functions. Enter the complete URL with all parameters expected by the receiving device as the HTTP request.
  • Page 33: Access From Own Applications

    Access from own applications 10. Access from own applications In addition to the SIP access, the SIP Ring Switch also offers the option of accessing from your own application. This can be done via TCP/IP sockets from the common high-level languages. However, it is also possible to use common web techniques such as AJAX or PHP to communicate with the web IO.
  • Page 34: Http Request

    Access from own applications HTTP request In addition to socket access the SIP Ring Switch can be addressed directly via HTTP using HTTP requests. By default this access is blocked and must first be enabled using Communication paths » Web-API. A detailed description of the supported HTTP requests and more details about access using Web techniques such as AJAX and PHP can be found in the Web-IO program- ming manual (download at http://www.WuT.de).
  • Page 35: Appendix

    Appandix 11. Appendix Alternatives for IP address assignment In case IP addresses cannot be assigned using DHCP or the Wutility Tool, the Web IO offers two further options: Assigning the IP address using the ARP command This method can be used when the SIP Ring Switch does not yet have an IP address and the entry is 0.0.0.0.
  • Page 36: Firmware Update

    The current firmware for your SIP Ring Switch can be found on the respective Web data sheet page at www.WuT.de/article number, e.g. www.wut.de/57753 To install the firmware update, you need a Windows PC with the WuTility tool installed (included in the firmware archive) and unrestricted network access to the SIP Ring Switch.
  • Page 37: Technical Data

    Technical data 12. Technical data Connections, displays and control elements: Digital outputs: 4 channels as output: 12-24V DC / 500mA per channel Total fuse protection for all outputs 3A Integrated 32-bit pulse counter Network: 10/100BaseT autosensing Power supply: 12 … 24V DC (approx. 100mA@24V) Output supply 12 …...