10、 PC Configuration Instructions
The figure below shows the display interface of the E90-DTU SL configuration host computer. The user can switch to the
command mode through M0M1, and quickly configure and read parameters on the host computer.
In the configuration host computer, the module address, frequency channel, network ID, and key are all in decimal display mode,
and the value range of each parameter is:
website address: 0~65535
Frequency channel: 0~83
Network ID: 0~255
key: 0~65535
When using the host computer to configure the relay mode, the user needs to pay special attention. Since the parameters in the
host computer are in decimal display mode, the module address and network ID need to be converted when filling in. For
example, if the network ID input by transmitter A is 02, and the network ID input by receiver B is 10, then when the relay
terminal R sets the module address, convert the hexadecimal value 0X020A to the decimal value 522 and fill it in as the relay
terminal R module address. That is, the module address value that needs to be filled in at the relay terminal R at this time is 522.