Faults and what to do about them.

Faults
Water is leaking from the
machine.
Water not flowing in.
Detergent is not being dis-
pensed.
The door will not open.
The programme does not
start.
Cause/remedy
Run the Drum Clean 90 °C programme or a 60 °C programme to clean and care
for the drum and the outer tub.
Notes
Run the programme without laundry.
Use standard washing powder or a detergent that contains bleach. To prevent
foaming, only use half the amount of detergent recommended by the detergent
manufacturer. Do not use detergents intended for woollens or delicates.
Switching the information signal on/off
Too much foam has been detected and additional rinse cycles have been activated.
Add less detergent to the next wash cycle with the same load.
At the end of the programme.
Not an appliance fault – the unbalanced load detection system has interrupted the
spin cycle because the laundry is unevenly distributed.
Distribute small and large items of laundry evenly in the drum. Spin the laundry
again if necessary.
There is water in the base trough; the appliance is leaking. Turn off the tap. Call the
after-sales service. ~ Page 44
The drain pump is blocked. Clean the drain pump. ~ Page 37
The drain hose/drain pipe is blocked. Clean the drain hose at the siphon.
~ Page 38
Switch off the appliance, wait for five seconds and then switch it on again. If the indi-
cator appears again, call the after-sales service. ~ Page 44
Cause/remedy
Attach the drain hose correctly or replace it.
Tighten the threaded joint on the supply hose.
Will the programme start?
Is the tap turned on?
Could the filter be clogged? Clean the filter.~ Page 39
Is the supply hose kinked or trapped?
The safety function is active. Do you want to stop the programme?
~ Page 34
Have you selected $ (Rinse Stop = no final spin)? ~ Page 34
Can the door only be opened by the emergency release? ~ Page 39
When switching from a programme that uses active oxygen to one that
does not, the door will remain locked for up to 25 minutes until there is no
longer any active oxygen in the drum.
Have you started the programme or selected Finished in-time?
Is the door closed?
Is the childproof lock activated? Deactivate. ~ Page 33