Code
Description
S2 probe broken
WP05
or malfunction-
ing
Probes broken or
WP06
malfunctioning
WP07
Fan not working
WP08
--
Humidity probe
WP09
broken or mal-
functioning.
Max. tempera-
ture allowed by
WP10
the safety ther-
mostat reached
Max. permitted
WP11
motor tempera-
ture reached
NOTIFICATIONS
Symbol
Description
T
Setpoint temperature
setpoint
T
Temperature measured by probe S1
S1
T
Temperature measured by probe S2
S2
T
Average of S1 and S2 temperatures
average
D
Difference in temperature between S1 and S2
T
H
Humidity setpoint
setpoint
timeout
Detection time (generic)
t
Blackout duration
black
t
Door opening duration
door
t
Repasteurization duration
repast
Conditions
1) S2 does not measure/fail
state
2) S1 working correctly
1) S1 does not measure/fail
state
2) S2 does not measure/fail
state
1) Evereo ON
2) S1 working correctly
3) S2 working correctly
4) D
> 10°C
T
5) timeout > 30 min.
--
1) Evereo ON
2) Humidity probe does
not measure/fail state
1) Safety thermostat digital
alarm input ON
1) Motor thermal alarm
digital input ON
String displayed
(ENGLISH)
WARNING WP05
PROBE ERROR
(PROBE 2)
WARNING WP06
PROBES ERROR
(PRESERVE FOOD
IN ANOTHER WAY)
WARNING WP07
FAN ERROR (PRE-
SERVE FOOD IN
ANOTHER WAY)
--
WARNING WP09
PROBE ER-
ROR (HUMIDITY
PROBE)
WARNING WP10
TEMPERATURE
THERMOSTAT
WARNING WP11
FAN THERMO-
STAT