ALARMS
Symbol
Description
T
Setpoint temperature
setpoint
T
Temperature measured by probe S1
S1
T
Temperature measured by probe S2
S2
T
Average of S1 and S2 temperatures
average
D
Difference in temperature between S1 and S2
T
timeout
Detection time (generic)
t
Blackout duration
black
t
Door opening duration
door
t
Repasteurization duration
repast
The holding cabinet detects and flags up the following hardware malfunctions:
Code
Description
Setpoint tem-
perature not
reached, within
WP01
30 minutes of
start-up of ma-
chine.
Temperature
lower than set
WP02
point, during
operation of the
machine.
Temperature ex-
WP03
ceeds maximum
value
S1 probe broken
WP04
or malfunction-
ing
66
Conditions
1) Evereo ON
2) At least ONE probe op-
erating
3) The door is closed
4) T
< T
average
setpoint
5) timeout > 30 min.
1) Evereo ON
2) At least ONE probe
operating
3) The door is closed
4) T
< T
average
setpoint
5) timeout > 30 min.
1) Evereo ON
2) At least ONE probe
operating
3) T
or T
or T
S1
S2
average
1) S1 does not measure/fail
state
2) S2 working correctly
String displayed
(ENGLISH)
WARNING WP01
LOW TEMPERA-
TURE (HEATING
ELEMENT ERROR)
WARNING WP02
LOW TEMPERA-
TURE (PRESERVE
FOOD IN ANOTH-
- 0.5°C
ER WAY)
WARNING WP03
HIGH TEMPERA-
TURE (HEATING
ELEMENT ERROR)
> 100°C
WARNING WP04
PROBE ERROR
(PROBE 1)

Advertisement