Operating Hours Counter L - Miele DA 5690 W Operating And Installation Instructions

Table of Contents

Advertisement

Operation

Operating hours counter l|

The number of hours the appliance has
been in operation is stored in memory.
The operating hours counters tell you
when the grease filters or charcoal filter
need to be cleaned or replaced.
Checking the grease filter operating
hours counter
After 30 hours of operation (or another
time if the operating hours counter has
been altered), the l sensor will light
up.
The grease filters must then be cleaned
and the operating hours counter reset
(see "Cleaning and Care").
To check the percentage of time set
already used:
^ Touch the s sensor to switch the fan
on.
^ Touch and hold the l sensor.
One or more of the 1 to 4 sensors will
flash.
The number of flashing sensors
indicates the percentage of the
operating time which has already been
used up.
Sensor 1
Sensors 1 and 2 = 50 %
Sensors 1 to 3
Sensors 1 to 4
The number of operating hours used
remains in the memory, even when the
appliance is switched off or there is a
power cut.
16
= 25 %
= 75 %
= 100 %
Altering the grease filter operating
hours counter
You can set the operating hours
counter to suit the type of cooking you
do.
The operating hours counter is set at
the factory for 30 hours.
Select a shorter time of 20 hours if you
fry a lot.
If you only cook occasionally, we still
recommend 20 hours because grease
which has built up gradually over a long
period of time will harden on the grease
filters and make cleaning more difficult.
If you use very little fat for cooking,
select a longer time of 40 or 50 hours.
To alter the operating time:
^ Touch the s sensor to switch the fan
off.
^ Touch the m and l sensors at the
same time.
The grease filter sensor l and one of
the fan power level sensors 1 to 4 will
flash.
Sensors 1 to 4 indicate the time set:
Sensor 1 = 20 hours
Sensor 2 = 30 hours
Sensor 3 = 40 hours
Sensor 4 = 50 hours
^ Touch the 1 sensor to select a shorter
time and the 4 sensor to select a
longer time, until the time required
has been set.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Da 5690 w ext

Table of Contents