12 Option description and instructions
Note: Drives with the Emergency stop, stop category 1 function (option +Q952 or +Q964):
If the user activates the POUS function during the emergency stop deceleration ramp, it
overrides the emergency stop function. This activates the STO function of the drive
immediately and the motor coasts to a stop. For more information on the emergency stop
function, see the appropriate user's manual.
The design principles of the option +Q957 comply with EN 1037.
The STO function complies with EN/IEC 61800-5-2:2007.
For a complete list of related standards and European directives, see section
Related
standards and directives
on page 23.