ELECTRIC DRYER INSTALLATION REQUIREMENTS
Direct Wire
Ch)
4
Fire Hazard
Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Electrical Requirements - Canada only
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
@
Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), covered with flexible metallic conduit.
All current-carrying wires must be insulated.
@
10-gauge solid copper wire (do not use aluminum).
@
Atleast 5 ft. (1.52 m) long.
A WARNING
°
Electrical Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
It is your responsibility:
@
To contact a qualified electrical installer.
@
To be sure that the electrical connection is adequate and in
conformance with the Canadian Electrical Code, C22.1
— latest
edition and all local codes. A copy of the above codes standard
may be obtained from: Canadian Standards Association,
178 Rexdale Blvd., Toronto, ON M9W
1R3 CANADA.
@
To supply the required 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply on a separate 30-amp circuit,
fused on both sides of the line. A time-delay fuse or circuit
breaker is recommended. Connect to an individual branch
circuit.
@
This dryer is equipped with a CSA International
Certified Power Cord intended to be plugged
O
into a standard 14-30R wall receptacle. The cord
]
is 5 ft (1.52 m) in length. Be sure wall receptacle
al
is within reach of dryer's final location.
4-Wire
Receptacle
(14-30R)
12
@
Do not use an extension cord.
If you are using a replacement power supply cord, it is
recommended that you use Power Supply Cord Replacement
Part Number 9831317. For further information, please reference
the service numbers located in the "Assistance or Service"
section.
GROUNDING INSTRUCTIONS
@ For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS