ELECTRICAL CONNECTIONS
POWER CORD AND STRAIN
3
RELIEF INSTALLATION
A
Remove the wire cover (on the lower
back of the range) by removing its top
center screw.
Do not discard this screw.
B
Remove the knockout ring (1
on bracket directly below the terminal
block. To remove the knockout, use a
pair of pliers to bend the knockout ring
away from the bracket and twist until
ring is removed.
Knockout ring
in bracket
Installation Instructions
") located
3
8
Terminal block
(appearance
may vary)
Knockout
ring removed
16
(CONT.)
For power cord installations only (see
C
the next step if using conduit), assemble
the strain relief in the hole. Insert the
power cord through the strain relief and
tighten. Allow enough slack to easily
attach the cord terminals to the terminal
block. If tabs are present at the end of
the winged strain relief, they can be
removed for better fit.
NOTE: Do not install the power cord
without a strain relief. The strain relief
bracket should be installed before
reinstalling the rear range wiring cover.
Strain relief
Power cord
Skip to Step 4 or 5.
D
For conduit installations only, purchase a
squeeze connector matching the diameter
of your conduit and assemble it in the hole.
Insert the conduit through the squeeze
connector and tighten. Allow enough slack to
easily attach the wires to the terminal block.
NOTE: Do not install the conduit without a
squeeze connector. The squeeze connector
should be installed before reinstalling the
rear range wiring cover.
Squeeze
connector
Conduit
Skip to Step 6 or 7.
Terminal
block
Bracket
Terminal
block
Bracket