Download Print this page

GE Range Installation Instructions

Range

Advertisement

Installation Instructions

Range
Questions?
Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com
IN THE COMMONWEALTH OF
When using ball type gas shut-off valves, they
shall be the T-handle type.
MASSACHUSETTS
A flexible gas connector, when used, must not
This product must be installed by a licensed
exceed 3 feet.
plumber or gas fitter.
When installing a gas appliance the use of old
WARNING
flexible connectors can cause gas leaks and
personal injury. Always use a NEW flexible
FIRE OR EXPLOSION HAZARD
connector.
If the information in this manual is not followed
Leak testing of the appliance shall be conducted
exactly, a fire or explosion may result causing
according to the manufacturer instructions.
property damage, personal injury or death.
The range must be electrically grounded in
Installation must be performed by a qualified
accordance with local codes or, in the absence
installer.
of local codes, in accordance with the National
Electrical Code (ANSI/NFPA 70, latest edition).
Read these instructions completely and carefully.
In Canada, electrical grounding must be in
Installation of this range must conform with
accordance with the current CSA C22.1 Canadian
local codes, or in the absence of local codes,
Electrical Code Part 1 and/or local codes. See
with the National Fuel Gas Code, ANSI Z223.1/
Electrical Connections in this section.
NFPA.54, latest edition. In Canada, installation
Do not install this product with an air curtain
must conform with the current Natural Gas
hood or other range hood that operates by
Installation Code, CAN/CGA-B149.1 or the current
blowing air down on the cooktop. This airflow
Propane Installation Code, CAN/CGA-B149.2, and
may interfere with operation of the gas burners
with local codes where applicable. This range
resulting in fire or explosion hazard.
has been design-certified by CSA International
according to ANSI Z21.1, latest edition and
Canadian Gas Association according to CAN/
CGA-1.1 latest edition.
DIMENSIONS AND CLEARANCES
Provide adequate clearances between the
thick), .015" (.38 mm) thick stainless steel, .025"
range and adjacent combustible surfaces. These
(0.64 mm) aluminum or .020" (0.5 mm) copper.
dimensions must be met for safe use of your
Installation of a listed microwave oven or
range.
cooking appliance over the cooktop shall
Allow 30" (76.2 cm) minimum clearance between
conform to the installation instructions packed
burners and bottom of unprotected wood or
with that appliance.
metal cabinet, or allow a 24" (61 cm) minimum
For island installation, maintain 2-1/2" minimum
when bottom of wood or metal cabinet is
from cutout to back edge of countertop and
protected by no less than 1/4" (6.4 mm) thick
3" minimum from cutout to side edges of
flame-retardant millboard covered with no less
countertop.
than No. 28 MSG sheet metal (.015" [.38 mm]
31 1/4"
2 1/2"
36 1/2"
26 1/2"
w/o handle
29 3/16"
w/ handle
30"
47 1/2"
Minimum to
cabinets on
Maximum
either side
depth for
of the range
30"
cabinets above
countertops
30"
6"
6"
13"
Minimum
Minimum
Minimum
18"
clearance
clearance to
to left wall
right wall
Front edge
of the range
To cabinets
side panel
below cooktop
forward from
and at the
0"
cabinet
range back
1/4"
SH 1 of 2 31-10898-2 07-13 GE
FOR YOUR SAFETY:
WARNING
If you did not receive an anti-tip bracket with your
purchase, call 1.800.626.8774 to receive one at no
cost. (In Canada, call 1.800.561.3344.) For installation
instructions of the bracket, visit: www.GEAppliances.com.
(In Canada, www.GEAppliances.ca.)
DIMENSIONS AND CLEARANCES (CONT.)
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
Recommended area for
120V outlet on rear wall and
area for through-the-wall
connection of pipe stub and
shut-off valve.
35"
to
36-1/2"
from floor to
countertop
Recommended area
for through-the-floor
24"
connection of pipe stub
Max
and shut-off valve.
from affecting burner operation, seal
all openings in floor under appliance
and behind appliance wall.
0"
To cabinets
below cooktop
and at the
range back
TOOLS YOU WILL NEED
Anti-Tip Bracket
Kit Included
Phillips
screwdriver
Open-end or
adjustable wrench
Flat-blade
WARNING
Before beginning
screwdriver
the installation, switch power off at
service panel and lock the service
Level
disconnecting means to prevent power
Pencil and ruler
from being switched on accidentally.
When the service disconnecting means
Drill, awl or nail
cannot be locked, securely fasten a
Pipe wrenches (2)
prominent warning device, such as a
(one for backup)
tag, to the service panel.
1/4" Nut Driver
Drill with 1/8" Bit
Tape Measure
Pliers
Safety Glasses
Tin Snips
CONVERTING TO LP GAS
(OR CONVERTING BACK TO
NATURAL GAS FROM LP)
This range leaves the factory set for use with
natural gas. If you want to convert to LP
gas, the conversion must be performed by a
qualified LP gas installer.
The conversion orifices and instructions can be
found on back of the range.
Keep these instructions and all orifices in case
you want to convert back to natural gas.
CAUTION
To prevent drafts
MATERIALS YOU MAY NEED
BEFORE YOU BEGIN
Gas line shut-off valve
Save these instructions for
Pipe joint sealant or UL-approved pipe thread
local inspector's use.
tape with Teflon* that resists action of natural
Observe all governing
and LP gases
codes and ordinances.
Flexible metal appliance connector (1/2" I.D.).
A 5-foot length is recommended for ease of
Remove all packing
installation but other lengths are acceptable.
material and literature from oven before
connecting gas and electrical supply to range.
Never use an old connector when installing a
new range.
To avoid damage to your
Flare union adapter for connection to gas
cabinets, check with your builder or cabinet
supply line (3/4" or 1/2" NPT x 1/2" I.D.)
supplier to make sure that the materials used will
not discolor, delaminate or sustain other damage.
Flare union adapter for connection to pressure
This oven has been designed in accordance with
regulator on range (1/2" NPT x 1/2" I.D.)
the requirements of UL and CSA International
Liquid leak detector or
and complies with the maximum allowable wood
soapy water.
cabinet temperatures of 194°F (90°C).
Squeeze Connector
Note to Installer – Be sure to leave these
(For Conduit Installations Only)
instructions with consumer.
(UL Listed 40 AMP)
Note to consumer – Keep these instructions for
4-Wire Cord 4' long OR
future reference.
3-Wire Cord 4' long
Servicer – The electrical diagram is in an
envelope attached to the back of the range.
*Teflon: Registered trademark of DuPont
Proper installation is the responsibility of the
installer.
Product failure due to improper installation is not
covered under warranty.
Rear of Range
Orifice Box
(location
may vary)
Before installing your range on linoleum or any
other synthetic floor covering, make sure the
floor covering can withstand 180°F without
shrinking, warping or discoloring. Do not install
the range over carpeting unless a sheet of 1/4"
thick plywood or similar insulator is placed
between the range and carpeting.
Mobile Home - Additional Installation
Requirements
The installation of this range must conform to
the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction
and Saftey, Title 24, HUD Part 280). When such
standard is not applicable, use the Standard for
Manufactured Home Installations, ANSI A225.1/
NFPA 501A or with local codes.
In Canada, the installation of this range must
conform with the current standards CAN/CSA-
A240-latest edition, or with local codes.
When this range is installed in a mobile home, it
must be secured to the floor during transit. Any
method of securing the range is adequate as
long as it conforms to the standards listed above.

Advertisement