Download Print this page
Stanley STHT77502-1 Manual
Stanley STHT77502-1 Manual

Stanley STHT77502-1 Manual

Self-leveling cross-line laser
Hide thumbs Also See for STHT77502-1:

Advertisement

Quick Links

STHT77502-1 & STHT77592-1
Self-Leveling Cross-line Laser
www.2helpU.com
Please read these instructions before operating the product.
GB
D
F
I
ES
PT
NL
DK
SE
FIN
NO
PL
GR
CZ
RU
HU
SK
SI
BG
RO
EE
LV
LT
TR
HR
DOC100270398

Advertisement

loading

Summary of Contents for Stanley STHT77502-1

  • Page 1 STHT77502-1 & STHT77592-1 Self-Leveling Cross-line Laser www.2helpU.com Please read these instructions before operating the product. DOC100270398...
  • Page 2 Figures...
  • Page 3 1/4-20...
  • Page 4 Figures...
  • Page 6 Figures...
  • Page 8 Figures...
  • Page 9 Laser Information Hazardous Radiation. Use of controls or adjustments, or performance of procedures, The STHT77502-1 and STHT77592-1 lasers are Class 2 laser products. The lasers are self-leveling laser in hazardous radiation exposure. tools that can be used for horizontal (level) and vertical (plumb) alignment projects.
  • Page 10 • Do not use the laser if the Power/Transport Lock switch does not turn the laser on or off. Any tool that injury. To locate your nearest Stanley service center cannot be controlled with the switch is dangerous go to http://www.2helpU.com.
  • Page 11 Installing AA Batteries • the laser is not level (or plumb) and should NOT BE USED for repositioning the laser on a level surface. STHT77592-1 laser. On the bottom of the laser, lift up the latch to a project. (Figure •...
  • Page 12 Where the horizontal beam crosses the center of Turn the laser 180º. (Figure (Figure Turn the laser 180º Where the horizontal beam crosses the vertical (Figure Turn the laser so the vertical beam is aimed at the second corner (Figure Turn the laser 180º...
  • Page 13 of the laser unit along the side vertical beam, and (Figure locations , and (Figure Where the top of the laser beam appears at the top of the door jamb, mark + 0.75mm), please bring the Move the laser to the opposite side of the door service jamb (Figure center for calibration.
  • Page 14 Using the Laser with Other Accessories WARNING: or pole. Since accessories other than those offered by STANLEY have not been tested with this laser, use of such accessories with this laser • could be hazardous. or back of the laser (Figure...
  • Page 15 The Laser Does Not Turn On warranties on the product. • • authorized service centers. Service or maintenance compartment. service • center, go to http://www.STANLEY.com. or corrosion. Two Year Warranty • leakage. • • When using rechargeable batteries, make sure the purchase to: Stanley UK Sales Limited •...
  • Page 16 NOTE: The customer is responsible for the correct use and care of the instrument. Moreover, the customer is calibration of the instrument. STHT77502-1 STHT77592-1 Light Source Laser diodes Laser Wavelength 630 – 680 nm visible 510 – 530 nm visible Operating Temperature -10°C to 40°C (14°F to 104°F)
  • Page 17 • Wartung führen. • Fehlerbehebung • Service und Reparaturen BEWAHREN SIE DIESE ANWEISUNGEN AUF WARNUNG: Informationen zum Laser Die Laser STHT77502-1 und STHT77592-1 auftreten. WARNUNG: Die Verwendung von Steuerelementen oder Anpassungen Benutzersicherheit sowie die Durchführung von Verfahren, die nicht den hierin beschriebenen entsprechen, Sicherheitsrichtlinien kann zu gefährlicher Strahlenbelastung...
  • Page 18 WARNUNG: LASERSTRAHLUNG. • Schalten Sie den Laser aus, wenn er nicht BLICKEN SIE NICHT IN DEN verwendet wird. Wenn der Laser eingeschaltet STRAHL. Laserprodukt der Klasse 2. bleibt, erhöht sich das Risiko, dass jemand in den Laserstrahl blickt. • vor. Veränderungen am Werkzeug können zu gefährlicher Laserstrahlung führen.

This manual is also suitable for:

Stht77592-1