Siemens WQ45G2D5NL User Manual And Installation Instructions page 42

Table of Contents

Advertisement

NLTroubleshooting
Malfunction
Device pauses,
but the drum
turns.
Creasing.
and program
broken.
42
Cause and Troubleshooting
Cooling process active.
No error - no action required.
The load amount is too high.
Observe the maximum load quantity of the
→ "Programs", page 26 .
The laundry has been in the drum for too long after drying.
Remove the laundry from the drum immediately after
1.
drying.
Spread out the items to let them cool.
2.
Unsuitable program for the type of fabric set.
Set the suitable program for the type of fabric.
→ "Programs", page 26
Easy care textiles dried too long.
"Change dryness target", page 25 .
→ "Adjust dryness target", page 25 .
Anti-crease not activated.
Activate the anti-crease program.
→ "Buttons", page 23
Condensed water container filled.
→ "Empty the condensed water container", page 33 .
1.
→ "Insert the condensed water container",
2.
page 34 .
→ "Starting the program", page 30 .
3.
Water drain hose is kinked or pinched.
Make sure that the water drain hose is not kinked or
1.
trapped.
Lay the water drain hose without kinks.
2.
Water drain hose is not connected correctly.
Make sure that the water drain hose is correctly
connected.
→ "Connect the water drain hose", page 14
Water drain hose is clogged.
Flush the water drain hose with tap water.
The filter in the condensation tank is dirty.
"Clean the filter in the condensation tank.",
page 40 .