Mounting the mounting brack-
ets (e.g. in concrete)
Mark the installation holes of the
mounting brackets 6 on the wall:
Ensure a 20 cm space above the
mounting brackets.
The front profile of the extracted
awning must be installed at
least 250 cm above the ground.
To achieve this distance at an
inclination of the awning of 15°,
the mounting brackets have to be
installed at a height of 330 cm.
All brackets have to be installed
at the same height. The dis-
tance between the insides of the
mounting brackets is:
10328411: 2690 mm
10328412: 1745 mm
10328413: 1900 mm
10328415: 1800 mm
The distance between the insides
of the four holes per mounting
bracket is 9 cm.
According to your wall type, drill
the holes and install the mount-
ing brackets with appropriate
fastenings. Ensure they are
securely fixed in place.