SCHUNK MMS-P22 Assembly And Operating Manual

SCHUNK MMS-P22 Assembly And Operating Manual

Magnetic switch

Advertisement

Assembly and Operating Manual
MMS-P22 / MMSK-P22 
Magnetic switch
Translation of Original Operating
Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MMS-P22 and is the answer not in the manual?

Questions and answers

Summary of Contents for SCHUNK MMS-P22

  • Page 1 Assembly and Operating Manual MMS-P22 / MMSK-P22  Magnetic switch Translation of Original Operating Manual...
  • Page 2 Best regards, Your SCHUNK team Customer Management Tel. +49-7133-103-2503 Fax +49-7133-103-2189 cmg@de.schunk.com Please read the operating manual in full and keep it close to the product. 01.00 | MMS-P22 / MMSK-P22 | Assembly and Operating Manual | en | 1566688...
  • Page 3: About This Manual

    This operating manual applies to the following variations: MMS-P22 / MMSK-P22 MMS-P22 / MMSK-P22 -SA, with lateral cable outlet MMS-P22 / MMSK-P22 -HD, with stainless steel housing 01.00 | MMS-P22 / MMSK-P22 | Assembly and Operating Manual | en | 1566688...
  • Page 4: Warranty

    The scope of delivery includes Magnetic switch MMS-P22 / MMSK-P22 in the version ordered Assembly and Operating Manual Accessory pack (incl. magnetic teaching tool, ID 301030) 01.00 | MMS-P22 / MMSK-P22 | Assembly and Operating Manual | en | 1566688...
  • Page 5: Inappropriate Use

    Structural changes should only be made with the written approval of SCHUNK. 01.00 | MMS-P22 / MMSK-P22 | Assembly and Operating Manual | en | 1566688...
  • Page 6: Personnel Qualification

    Before working with the product, the personnel must have read and understood the complete assembly and operating manual. Observe the national safety regulations and rules and general safety instructions. 01.00 | MMS-P22 / MMSK-P22 | Assembly and Operating Manual | en | 1566688...
  • Page 7: Technical Data

    Ambient temperature [°C] Min. Max. Nominal voltage [VDC] Min. Max. IP rating More technical data is included in the catalog data sheet. Whichever is the latest version. 01.00 | MMS-P22 / MMSK-P22 | Assembly and Operating Manual | en | 1566688...
  • Page 8: Assembly And Settings

    The sensor is an electronic component that can be sensitive to high-frequency interference or electromagnetic fields. Check whether there is sufficient distance between the sensor and sources of interference and their supply cables. 01.00 | MMS-P22 / MMSK-P22 | Assembly and Operating Manual | en | 1566688...
  • Page 9: Electrical Connection

    Connect the sensor (1) and fasten the cable. Secure the electronics with cable connectors to relieve the stress on the cable. ð Use the ribs on the electronics to fasten the cable. 01.00 | MMS-P22 / MMSK-P22 | Assembly and Operating Manual | en | 1566688...
  • Page 10: Adjusting The Sensor

    The switch-off point must then be taught closer to the switch-on point. 01.00 | MMS-P22 / MMSK-P22 | Assembly and Operating Manual | en | 1566688...
  • Page 11 ð LED 1 (1) flashes twice. Move module to Switch-off point for switching point 2 position. Briefly press the "Teach" button (2). ð LED 2 (3) flashes twice. 01.00 | MMS-P22 / MMSK-P22 | Assembly and Operating Manual | en | 1566688...
  • Page 12: Troubleshooting

    10 mm. NOTE If these steps do not eliminate the problem, contact SCHUNK Service for troubleshooting. 01.00 | MMS-P22 / MMSK-P22 | Assembly and Operating Manual | en | 1566688...
  • Page 13: Translation Of The Original Declaration Of Conformity

    Requirements for proximity devices with analogue output (IEC 60947-5-7:2003) Signed for and on behalf of: SCHUNK SE & Co. KG Lauffen/Neckar, September 2023 i.V. Nico Peper;Director Software and Electronics;Technology & Innovation 01.00 | MMS-P22 / MMSK-P22 | Assembly and Operating Manual | en | 1566688...
  • Page 14 Marcel Machado, address: refer to manufacturer's address Signed for and on behalf of: SCHUNK SE & Co. KG Lauffen/Neckar, September 2023 i.V. Nico Peper;Director Software and Electronics;Technology & Innovation 01.00 | MMS-P22 / MMSK-P22 | Assembly and Operating Manual | en | 1566688...
  • Page 15 "on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)", or fulfill their intended function only as part of one. Therefore products from SCHUNK do not fall within the scope of the directive at this time. REACH Regulation Products from SCHUNK fully comply with the regulations of Regulation (EC) No. 1907/2006...
  • Page 16 SCHUNK SE & Co. KG Toolholding and Workholding | Gripping Technology | Automation Technology Bahnhofstr. 106 - 134 D-74348 Lauffen/Neckar Tel. +49-7133-103-0 Fax +49-7133-103-2399 info@de.schunk.com schunk.com Folgen Sie uns I Follow us Wir drucken nachhaltig I We print sustainable...