Page 1
Assembly and Operating Manual MMS 22-PI1-EX/MMSK 22-PI1-EX Magnetic switch Translation of Original Operating Manual...
Page 2
Best regards, Your SCHUNK team Customer Management Tel. +49-7133-103-2503 Fax +49-7133-103-2189 cmg@de.schunk.com Please read the operating manual in full and keep it close to the product. 02.00 | MMS 22-PI1-EX/MMSK 22-PI1-EX | Assembly and Operating Manual | en | 1566685...
1.1.3 Variants This operating manual applies to the following variations: MMS 22-PI1 ... EX MMSK 22-PI1 ... EX, cable version with open wire strands 02.00 | MMS 22-PI1-EX/MMSK 22-PI1-EX | Assembly and Operating Manual | en | 1566685...
Accessory pack (incl. magnetic teaching tool, ID 301030) 1.4 ATEX certification II 2 G Ex mb IIC T6 Gb II 2 D Ex tb IIIC T85°C Db KEMA 08ATEX0130 X 02.00 | MMS 22-PI1-EX/MMSK 22-PI1-EX | Assembly and Operating Manual | en | 1566685...
Structural changes should only be made with the written approval of SCHUNK. 02.00 | MMS 22-PI1-EX/MMSK 22-PI1-EX | Assembly and Operating Manual | en | 1566685...
Before working with the product, the personnel must have read and understood the complete assembly and operating manual. Observe the national safety regulations and rules and general safety instructions. 02.00 | MMS 22-PI1-EX/MMSK 22-PI1-EX | Assembly and Operating Manual | en | 1566685...
Ambient temperature [°C] (fixed-installed cable) Min. Max. Nominal voltage [VDC] Min. Max. IP rating (sensor is connected) For further technical data, see the catalog data sheet. 02.00 | MMS 22-PI1-EX/MMSK 22-PI1-EX | Assembly and Operating Manual | en | 1566685...
For ferromagnetic adapter plates: First, install the module on the adapter plate. Then adjust the switching position of the sensor. 02.00 | MMS 22-PI1-EX/MMSK 22-PI1-EX | Assembly and Operating Manual | en | 1566685...
Type of switching : PNP Switching function: closer Variant MMS 22-PI1 ... EX: Connector M8 Variant MMSK 22-PI1 ... EX: 2 m cable, open wire strand Brown Supply voltage Black Output Blue 02.00 | MMS 22-PI1-EX/MMSK 22-PI1-EX | Assembly and Operating Manual | en | 1566685...
Page 10
Tighten the set-screw (3) to clamp the sensor (1) in this position in the groove (2). ð Observe the maximum tightening torque of 10 Ncm. Test the switching position. 02.00 | MMS 22-PI1-EX/MMSK 22-PI1-EX | Assembly and Operating Manual | en | 1566685...
Page 11
LED (2) flashes quickly for 2 s if the magnetic field is too large or too small. If there is a duplicate or unsuitable switching point, the sensor (3) should be moved by 2 mm and taught again. 02.00 | MMS 22-PI1-EX/MMSK 22-PI1-EX | Assembly and Operating Manual | en | 1566685...
Page 12
In this case, the switch-off point closer to the switch-on point must be taught. 02.00 | MMS 22-PI1-EX/MMSK 22-PI1-EX | Assembly and Operating Manual | en | 1566685...
10 mm. NOTE If these steps do not eliminate the problem, contact SCHUNK Service for troubleshooting. 02.00 | MMS 22-PI1-EX/MMSK 22-PI1-EX | Assembly and Operating Manual | en | 1566685...
Page 14
02.00 | MMS 22-PI1-EX/MMSK 22-PI1-EX | Assembly and Operating Manual | en | 1566685...
Page 15
02.00 | MMS 22-PI1-EX/MMSK 22-PI1-EX | Assembly and Operating Manual | en | 1566685...
Page 16
SCHUNK SE & Co. KG Toolholding and Workholding | Gripping Technology | Automation Technology Bahnhofstr. 106 - 134 D-74348 Lauffen/Neckar Tel. +49-7133-103-0 info@de.schunk.com schunk.com Folgen Sie uns I Follow us Wir drucken nachhaltig I We print sustainable...
Need help?
Do you have a question about the MMS 22-PI1-EX and is the answer not in the manual?
Questions and answers