Defrost stop temperature
d8
Dripping time
Delay time for displaying the
d9
cabinet temperature after defrost
d10
Defrost start delay
d11
Defrost mode
F1
Fan working mode
Fan start delay after the controller
F2
is energized
F3
Fan delay time after defrost
Duty cycle mode in the event of a
A1
faulty cabinet sensor
Compressor off time in duty cycle
A2
mode
Compressor on time in duty cycle
A3
mode
A4
Buzzer beep
A5
Low alarm temperature(cabinet)
A6
High alarm temperature(cabinet)
A7
Alarm delay
Alarm delay after switch-on of the
A8
device
A9
High alarm offset
A10 Low alarm offset
A11
Cabinet temperature alarm
0℃ ~ 50℃
32℉ ~122℉
0~60
0: Disabled
0~90
0~60
0: Disabled
0: Electric defrost
1: Hot gas defrost
0: Fan and compressor run or stop
simultaneously;
1: Fan runs continuously and stops
during defrost;
2: Fan runs continuously and stops
during defrost and dripping;
3: Fan runs continuously, stops during
defrost and delays after defrost;
4: Fan is controlled by defrost sensor
temperature, and stops during defrost.
0~60
0~60
0: Disabled
0: Disable
1: Enable
1~60
1~60
0: Disable
1: Enable
-50℃ ~ High alarm temperature
(cabinet)
-58℉ ~ High alarm temperature
(cabinet)
Low alarm temperature(cabinet) ~ 85℃
Low alarm temperature(cabinet) ~ 185℉
0~60
0~60
1℃ ~30℃
1℉~ 60℉
1℃ ~30℃
1℉~ 60℉
0: Absolute temperature point
1: Temperature set-point + alarm offset
14
℃/℉
12℃
2
min
10
min
10
min
0
/
3
/
3
min
2
min
1
/
5
min
30
min
1
/
℃/℉
-10℃
24℃
℃/℉
20
3min
40
3min
℃/℉
10℃
5℃
℃/℉
0
/