Installation; Technical Specifications - Lincoln Electric 9919 Operator's Manual

Hide thumbs Also See for 9919:
Table of Contents

Advertisement

A-1
TECHNICAL SPECIFICATIONS – DC-1000
Standard
Voltage
230/460/60
575/60
220/380/440/50/60
380/500/50/60
415/50/60
Duty Cycle
100% Duty Cycle
60% Duty Cycle
50% Duty Cycle
Output Range
150A/16V-1300A/46V
INPUT
VOLTAGE /
FREQUENCY
230
460
575
220
380
415
440
500
HEIGHT
30.75 in
781 mm
1 Also called "inverse time" or "thermal/magnetic" circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magnitude of the current increases.

INSTALLATION

INPUT - THREE PHASE ONLY
100% Duty Cycle
193/96.5
193/112/96.5
RATED OUTPUT
Maximum Open Circuit Voltage
75V for 60 HZ models
72V for 50/60 HZ models
RECOMMENDED INPUT WIRE AND FUSE SIZES
HERTZ
INPUT AMPERE
RATING ON
NAMEPLATE
60
193
60
96.5
60
77.2
50/60
193
50/60
112
50/60
102
50/60
96.5
50/60
85
PHYSICAL DIMENSIONS
WIDTH
22.25 in
567 mm
IDEALARC® DC-1000
Input Current at Rated Output
60% Duty Cycle
215/108
77.2
215/124/108
112/85
124/94
102
Amps
1000
1140
1250
OUTPUT
TYPE 75°C
COPPER WIRE
IN CONDUIT
AWG(IEC-MM
2
) SIZES
30°C (86°F) Ambient
000 (85)
3 (27)
4 (21)
000 (85)
2 (34)
2 (34)
3 (27)
4 (21)
DEPTH
39.0 in
991 mm
50% Duty Cycle
230/115
86
92
230/133/115
133/101
121
113
Volts at Rated Amperes
44
44
44
Auxiliary Power
See the OPERATION section
for Auxiliary Power
information by model
TYPE 75°C
TYPE 75°C
GROUND WIRE
(SUPER LAG)
IN CONDUIT
OR BREAKER
AWG(IEC-MM
2
) SIZES
SIZE (AMPS)
4 (21)
300 Amp
6 (14)
150 Amp
6 (14)
125 Amp
4 (21)
300 Amp
6 (14)
175 Amp
6 (14)
150 Amp
6 (14)
150 Amp
6 (14)
125 Amp
WEIGHT
821 lbs.
372 kg.
A-1